Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Subjective and objective image quality of low-dose CT images processed using a self-supervised denoising algorithm
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
This study aimed to assess the subjective and objective image quality of low-dose computed tomography (CT) images processed using a self-supervised denoising algorithm with deep learning. We trained the self-supervised denoising model using low-dose CT images of 40 patients and applied this model to CT images of another 30 patients. Image quality, in terms of noise and edge sharpness, was rated on a 5-point scale by two radiologists. The coefficient of variation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were calculated. The values for the self-supervised denoising model were compared with those for the original low-dose CT images and CT images processed using other conventional denoising algorithms (non-local means, block-matching and 3D filtering, and total variation minimization-based algorithms). The mean (standard deviation) scores of local and overall noise levels for the self-supervised denoising algorithm were 3.90 (0.40) and 3.93 (0.51), respectively, outperforming the original image and other algorithms. Similarly, the mean scores of local and overall edge sharpness for the self-supervised denoising algorithm were 3.90 (0.40) and 3.75 (0.47), respectively, surpassing the scores of the original image and other algorithms. The CNR and SNR for the self-supervised denoising algorithm were higher than those for the original images but slightly lower than those for the other algorithms. Our findings indicate the potential clinical applicability of the self-supervised denoising algorithm for low-dose CT images in clinical settings.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=17; title_english_function_words=3; title_english_share=0.1765; title_reads=english; abstract_words=233; abstract_english_function_words=82; abstract_english_share=0.3519; abstract_reads=english; language_check=metadata_listed