Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Low-Dose Dual-Source Computed Tomography for Evaluating Persistent Truncus Arteriosus Associated with Cardiovascular Anomalies: Comparison with Transthoracic Echocardiography
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
Abstract BackgroundTo assess the morphological features of persistent truncus arteriosus (PTA) on low-dose dual-source computed tomography (DSCT) and compare its diagnostic value for associated cardiovascular anomalies with that of transthoracic echocardiography (TTE).Methods:Twenty-four PTA patients were enrolled in this retrospective study. The types of PTA, diameters of the truncus artery (TA), main pulmonary artery (MPA), right pulmonary artery (RPA), left pulmonary artery (LPA), and ventricular septal defect (VSD) on DSCT were recorded. Besides, all associated cardiovascular abnormalities were assessed. The diagnostic performance of DSCT and TTE for associated anomalies were compared. The effective doses of DSCT were calculated.Results:Four types were found: type A1(n=13/24, 54.17%), type A2(n=7/24, 29.16%), type A3(n=3/24, 12.50%)and type A4(n=1/24,4.17%). The mean diameter of VSD, TA, MPA, RPA, and LPA was 1.47±0.56cm, 3.92±1.56cm, 2.27±1.65cm, 1.48±0.74cm and 1.38±0.66cm, respectively. 78 associated cardiovascular anomalies were confirmed. The most common associated abnormalities were VSD (100%), right-sided aortic arch (33.33%) and aortopulmonary collateral vessels (29.17%). Although TTE was better at diagnosing intracardiac anomalies (accuracy:99.17% vs. 95%; sensitivity: 97.06% vs. 88.24%; specificity: 100% vs. 97.67%), DSCT had an advantage in diagnosing the associated cardiovascular abnormalities (accuracy: 98.61% vs. 96.07%; sensitivity: 94.87% vs. 82.05%; specificity: 99.44% vs. 99.15%). The estimated mean effective doses was 0.98±0.37mSv (<1mSv). Conclusions:Low-dose DSCT could accurately confirm the morphological features of PTA. Compared to TTE, low-dose DSCT is a better diagnostic tool for associated cardiovascular abnormalities. Combining with TTE will be beneficial to provide more accurate information for clinical interventions.
From Crossref.
The criteria
-
Include if: The document is in English.
Unclear (checked by an automatic rule)What the rule found: language_in: language=; title_words=19; title_english_function_words=3; title_english_share=0.1579; title_reads=english; abstract_words=237; abstract_english_function_words=67; abstract_english_share=0.2827; abstract_reads=english; language_check=metadata_missing