Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

miRNA Detection for non-small cell lung cancer diagnosis

Carla Cruz; André Rico; Fani Pereira de Sousa; Bernardo Teixeira; Daniela Alexandre (2021). International Electronic Conference on Medicinal Chemistry (ECMC)

DOI 10.3390/ecmc2021-11506

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Lung cancer is the leading cause of cancer-related death worldwide, principally because of the late diagnosis. Non small lung cancer (NSCLC) accounts for about 80% of all lung malignancies. Most patients with NSCLC are diagnosed at an advanced stage and the current methods are low-dose computed tomography, magnetic resonance imaging, positron emission tomography and sputum cytology; however, the sensitivities are insufficient for early diagnosis and the rate of false-positive findings are higher.Circulating miRNAs have been investigated as biomarkers for NSCLC in blood, since they are stable and detectable. These miRNAs are showed an unusual expression profile. Peripheral blood mononuclear cells (PBMC’s) miRNA profile can be related to NSCLC stage and further diagnosis. Molecular beacons (MB) are oligonucleotides comprising a stem-loop structural configuration that enable specific nucleic acid sequence detection throughout fluorescence. In this work, we measure miRNAs in PBMC’sisolated from whole blood of NSCLC patients and healthy volunteers by Ficoll-Isopague centrifugation and identify the miRNA-155-3p and 5p by RT-qPCR analysis. After that it was performed the MB design for the targeting of miRNA-155. The characterization of the MB together with the synthetic miRNA-155-3p showed promising results, that confirm the specificity of MB as a method of detection to mir-155-3p. The results revealed that miRNA-155-3p is up-regulated in the patients comparing to the controls.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=1; title_english_share=0.1111; title_reads=english; abstract_words=226; abstract_english_function_words=84; abstract_english_share=0.3717; abstract_reads=english; language_check=metadata_listed