Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Ultra-low-dose coronary computed tomography angiography using photon-counting detector computed tomography

Suguru Araki; Satoshi Nakamura; Masafumi Takafuji; Yasutaka Ichikawa; Hajime Sakuma; Kakuya Kitagawa (2024). European Heart Journal - Imaging Methods and Practice

DOI 10.1093/ehjimp/qyae125

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Abstract Aims Photon-counting detector computed tomography (PCD-CT), which allows the exclusion of electronic noise, shows promise for significant dose reduction in coronary CT angiography (CCTA). This study aimed to assess the radiation dose and image quality of CCTA using PCD-CT, combined with high-pitch helical scanning and an ultra-low tube potential of 70 kVp, and investigate the effect of a sharp kernel on image quality and stenosis assessment in such an ultra-low-dose CCTA setting. Methods and results Forty patients (65% male) with stable heart rates and no prior coronary interventions were included. Data on CT dose index volume (CTDIvol) and dose-length product (DLP) were collected, with effective radiation dose estimated using a conversion factor of 0.014. Images were reconstructed using kernels of Bv64 and Bv40 for image quality and stenosis assessment. The mean CTDIvol, DLP, and effective dose of CCTA were 1.72 ± 0.38 mGy, 29.1 ± 6.8 mGy·cm, and 0.41 ± 0.09 mSv, respectively. Image quality was similar (P = 0.75) between the two kernels, with over 95% of segments achieving a rating of good image quality for both kernels. The per-segment stenosis score distribution between Bv40 and Bv64 reconstruction images showed significant differences for both non-calcified and calcified plaques (P < 0.001 for both). Conclusion PCD-CT technology with high-pitch helical scanning and the tube potential of 70 kVp can provide CCTA with ultra-low radiation exposure (DLP, 29 mGy·cm). The noise reduction capability of PCD-CT allows the use of a sharp kernel even in this low-dose CCTA setting without compromising image quality, potentially improving the evaluation of coronary artery stenosis.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=0; title_english_share=0.0000; title_reads=not_english; abstract_words=260; abstract_english_function_words=77; abstract_english_share=0.2962; abstract_reads=english; language_check=metadata_listed