Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

UAVENet: Unpaired Adversarial Vessel Enhancement for Low-Dose Contrast Computed Tomography Angiography Reconstruction

Zhan Wu; Jiaxi Hu; Yuehuai Zhang; Shangwen Yang; Tianling Lyu; Yang Chen (2025). IEEE Transactions on Instrumentation and Measurement

DOI 10.1109/tim.2025.3633364

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Computed tomography angiography (CTA) imaging instrumentation utilizing iodinated contrast medium (ICM) plays a pivotal role in vessel imaging, but its routine administration presents significant clinical risks. Although low-dose CTA (LDCTA) mitigates these concerns, it inherently compromises vascular contrast and structural clarity. Unpaired enhancement methods can intensify LDCTA images without routine-dose administration and the paired RDCTA-LDCTA images. However, due to the complicated anatomical vasculature and the low contrast between the vessels and the background, these current methods cannot focus on the vessel structure and further enhance the vessel intensity for LDCTA imaging. To overcome these limitations, we propose UAVENet, a novel unpaired adversarial LDCTA vessel enhancement network. Firstly, a bidirectional adversarial learning framework is proposed to facilitate domain translation between LDCTA and routine-dose CTA (RDCTA) images without paired data. Secondly, a local enhancement module is constructed to enhance the pixel representation in the vessel region and preserve background details. Thirdly, continuous consistency loss is designed to ensure inter-slice smoothness. Comprehensive validation reveals that the proposed UAVENet improves RMSE by 20.46%, PSNR by 4.78%, SSIM by 1.14%, SNR by 3.09%, and CNR by 5.51% over the state-of-the-art methods in the simulated dataset and obtains superior performance in clinical datasets, which can be utilized as a novel LDCTA imaging instrumentation for the quantitative measurement and assessment of vascular disease with low clinical contrast agents.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=13; title_english_function_words=1; title_english_share=0.0769; title_reads=not_english; abstract_words=224; abstract_english_function_words=71; abstract_english_share=0.3170; abstract_reads=english; language_check=metadata_missing