Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Accuracy of low-dose computed tomography (CT) for detecting and characterizing the most common CT-patterns of pulmonary disease

Andreas Christe; Jaled Charimo Torrente; Kingshuk Roychoudhury; Peter Vock; Justus Erasmus Roos (2012). European Journal of Radiology

DOI 10.1016/j.ejrad.2012.09.025

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease. METHODS AND MATERIALS: Sixty patients with nodules, consolidations or interstitial disease were scanned using a low-dose (128 mm × 0.6 mm, 40 reference mAs, 120 kVp) and standard-dose CT protocol (150 reference mAs, 120 kVp). Two radiologists with 3 and 10 years of thoracic imaging experience searched both exams in consensus for the most commonly observed CT patterns according to the Fleischner Society criteria, which consisted of 46 different subgroups of ground-glass opacities, nodules, interstitial and airspace diseases. The standard of reference was established by consensus of a panel of two experienced chest radiologists (9 and 12 years of experience). RESULTS: The lung segments (1080) showed 813 nodules, 596 ground-glass opacities, 74 airspace and 575 interstitial diseases and 64 normal segments. In particular, air-space disease and nodules were unaffected by the increase in noise. However, the sensitivity to detect ground-glass opacities, ground-glass nodules and interstitial opacities decreased significantly, from 89% to 77%, 86% to 68% and 91% to 71%, respectively (all p-values <0.00001). Using iterative reconstruction instead of the applied filtered back projection sensitivity for ground-glass nodules rose to the sensitivity of standard-dose CT in an additional phantom study. CONCLUSION: A low-dose CT of 40 mAs/120 kVp is feasible for detecting solid nodules, airspace, airways and pleural disease. For diagnosing pathologies consisting of ground-glass opacities or interstitial opacities, higher tube current or iterative reconstruction is required.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=6; title_english_share=0.3158; title_reads=english; abstract_words=233; abstract_english_function_words=74; abstract_english_share=0.3176; abstract_reads=english; language_check=metadata_listed