Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Artificial Intelligence-Assisted Pulmonary Nodule Detection Improves Accuracy and Efficiency in Lung Cancer Screening
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background and Objectives: Lung nodule detection and characterization in the low-dose computed tomographic (LDCT) screening is a time-consuming task. Computer-aided detection or computeraided diagnosis (CAD) has shown increased efficiency. The lung nodule training model based on open datasets, such as LUNA16, may produce higher false-positives (FP) and false-negatives (FN) in the presence of small nodules, especially in part solid or nonsolid nodules. This study aimed to develop a CAD system based on Taiwanese CT datasets to improve the efficiency for detecting and characterizing lung nodule(s) in lung cancer screening.<br><br>Methods: A total of 1,906 CT scans, from two open datasets LNDb and LUNA16 as well as the National Taiwan University Hospital (NTUH), were collected for AI model training (1847 CT scans) and reading performance assessment (59 CT scans). A total of 12 radiologists participated in this study. Each CT scan was read by at least 3 radiologists independently and confirmed at least twice if the nodule annotations were inconsistent among the readers. A web-based CAD system was constructed. The reading time, the consistency of the nodule annotations, and the reading performance were analyzed.<br><br>Results: The number of part-solid and non-solid nodules was more abundant in the NTUH dataset compared to LUNA16. The performance of the NTUH dataset re-trained AI model (sensitivity =0.895, avg. FP = 1.5) was better than that of the LUNA16 AI model (sensitivity = 0.673, avg. FP = 1.5). Compared to radiologists without CAD assistance, radiologists with CAD assistance were more efficient in terms of reading time (an average decrease of 29%), Fleiss’ kappa nodule classification (increased 31%), Fleiss’ kappa nodule lobe (grew 33%), lung nodule detection accuracy (rose 25% on avg.) and recall rate (improved 25% on avg.).<br><br>Conclusions: The AI models trained with local datasets show improvement of recall, reduction of false positives and increased efficiency of CT reading.
From Crossref.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=315; abstract_english_function_words=96; abstract_english_share=0.3048; abstract_reads=english; language_check=metadata_listed