Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

3D-DHA-MAFNet: A Multi-View Attention-Enhanced Deep Learning System for Lung Nodule Detection and Classification

Guigui Zhao; Qingchun Meng; Jingliang Zhang (2025). Informatica

DOI 10.31449/inf.v49i25.11184

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Lung cancer, one of the most lethal malignancies globally, has a high mortality rate, making early screening and accurate diagnosis crucial for improving patient survival rates. Low-dose computed tomography (LDCT) has significantly increased the detection rate of lung nodules, but the vast amount of imaging data poses a significant challenge for manual interpretation. This article proposed a lung nodule computer-aided quantitative diagnostic system based on a three-dimensional convolutional neural network (3D CNN), named 3D-DHA-MAFNet. By integrating deformable convolution network (DCN), hybrid attention mechanism (HAM), and multi-view adaptive fusion network (MAFN), this system significantly enhanced the detection and benign/malignant classification capabilities for small and irregular lung nodules. The model was trained and evaluated on the lung nodule analysis 2016 (LUNA16) and LIDC-IDRI datasets with a patient-level split in the ratio of 7:2:1. The number of training epochs was 200. Data augmentation methods included random rotation (±15°), translation (±5 pixels), and elastic deformation. The performance was compared with baseline models including 3D-UNet, AttentNet, 3DAGNet, 3D multi-scale capsule network (3D-MCN), and 3D multi-view SE CNN (3D MVSECNN). Experiments showed that on the LUNA16 dataset, the model achieved a detection sensitivity of 98.7% with a low false-positive rate of 1.2 per scan, which was a notable improvement over baseline models like 3D-UNet. On the LIDC-IDRI dataset, the classification accuracy for benign and malignant nodules reached 96.8%, with an AUC value of 0.983, and particularly, the sensitivity for malignant nodules was enhanced to 97.5%. Ablation studies verified the synergistic gains of each module, and cross-clinical dataset testing further demonstrated its strong generalization ability. This article presents a high-precision and interpretable intelligent diagnostic tool designed for clinical applications, which holds strong potential to promote the clinical translation of early lung cancer screening.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=3; title_english_share=0.1765; title_reads=english; abstract_words=294; abstract_english_function_words=84; abstract_english_share=0.2857; abstract_reads=english; language_check=metadata_listed