Ultra-low dose computed tomography protocols using spectral shaping for lung cancer screening: Comparison with low-dose for volumetric LungRADS classification
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
Purpose To compare Low-Dose Computed Tomography (LDCT) with four different Ultra-Low-Dose Computed Tomography (ULDCT) protocols for PN classification according to the Lung Reporting and Data System (LungRADS). Methods Three hundred sixty-one participants of an ongoing lung cancer screening (LCS) underwent single-breath-hold double chest Computed Tomography (CT), including LDCT (120kVp, 25mAs; CTDIvol 1,62 mGy) and one ULDCT among: fully automated exposure control ("ULDCT 1 "); fixed tube-voltage and current according to patient size ("ULDCT 2 "); hybrid approach with fixed tube-voltage ("ULDCT 3 ") and tube current automated exposure control ("ULDCT 4 "). Two radiologists (R1, R2) assessed LungRADS 2022 categories on LDCT, and then after 2 weeks on ULDCT using two different kernels (R1: Qr49 ADMIRE 4 ; R2: Br49 ADMIRE 3 ). Intra-subject agreement for LungRADS categories between LDCT and ULDCT was measured by the k-Cohen Index with Fleiss-Cohen weights. Results LDCT-dominant PNs were detected in ULDCT in 87 % of cases on Qr49 ADMIRE 4 and 88 % on Br49 ADMIRE 3 . The intra-subject agreement was: κULDCT 1 = 0.89 [95 %CI 0.82–0.96]; κULDCT 2 = 0.90 [0.81–0.98]; κULDCT 3 = 0.91 [0.84–0.99]; κULDCT 4 = 0.88 [0.78–0.97] on Qr49 ADMIRE 4 , and κULDCT 1 = 0.88 [0.80–0.95]; κULDCT 2 = 0.91 [0.86–0.96]; κULDCT 3 = 0.87 [0.78–0.95]; and κULDCT 4 = 0.88 [0.82–0.94] on Br49 ADMIRE 3 . LDCT classified as LungRADS 4B were correctly identified as LungRADS 4B at ULDCT 3 , with the lowest radiation exposure among the tested protocols (median effective doses were 0.31, 0.36, 0.27 and 0.37 mSv for ULDCT 1 , ULDCT 2 , ULDCT 3 , and ULDCT 4 , respectively). Conclusions ULDCT by spectral shaping allows the detection and characterization of PNs with an excellent agreement with LDCT and can be proposed as a feasible approach in LCS.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=21; title_english_function_words=3; title_english_share=0.1429; title_reads=english; abstract_words=240; abstract_english_function_words=64; abstract_english_share=0.2667; abstract_reads=english; language_check=metadata_listed