Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose, wide-detector array thoracic aortic CT angiography using an iterative reconstruction technique results in improved image quality with lower noise and fewer artifacts

Prabhakar Rajiah; Paul Schoenhagen; Dhruv Mehta; Thomas Ivanc; Michael Lieber; Kassem Soufan; Milind Desai; Scott D. Flamm; Sandra Halliburton (2012). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2012.04.009

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Iterative reconstruction techniques (IRTs) may improve image quality for low-dose imaging compared with filtered back projection (FBP) reconstruction. OBJECTIVES: We compared the results of an IRT for low-dose thoracic aortic computed tomography (CT) imaging with those from FBP reconstruction. METHODS: Data from 50 patients who underwent 256-slice CT for evaluation of the thoracic aorta were reconstructed with FBP and an IRT (iDose(4)) at 3 noise-reduction strengths (levels 2, 4, and 6). A blinded reader graded image quality (scale, 1-5; 5 = high diagnostic confidence) and the extent of shoulder artifact (scale, 1-5; 5 = no artifact) on all reconstructions. A second reader evaluated a subset of 20 cases to determine interreader and intrareader reproducibility. The mean and SD of attenuation were measured at 5 locations along the thoracic aorta and both subclavian arteries. RESULTS: Image noise (SD of attenuation) improved with IRT relative to FBP (aorta: FBP, 31.4 ± 8.6 HU; IRT level 2, 25.1 ± 6.9 HU; level 4, 21.7 ± 6.2 HU; level 6, 17.2 ± 5.4 HU; P < 0.0001; subclavian arteries: FBP, 92.7 ± 34.6 HU; IRT level 2, 50.1 ± 17.1 HU; level 4, 48.9 ± 18.6 HU; level 6, 45.2 ± 19.2 HU; P < 0.0001), whereas mean attenuation was unchanged. Increasing image quality was observed in the aorta and through the shoulders as the contribution from IRT to the final images increased (P < 0.0001). Significant differences were noted between readers in image quality assessment of the aorta but not through the shoulders. CONCLUSION: IRT is associated with reduced noise and shoulder artifact and allows for low-dose aortic CT imaging.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=25; title_english_function_words=4; title_english_share=0.1600; title_reads=english; abstract_words=223; abstract_english_function_words=71; abstract_english_share=0.3184; abstract_reads=english; language_check=metadata_listed