Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Evaluating the robustness of features generated by a foundation model from CT with different reconstruction parameters

S.H. Park; Anil Yadav; Hossein Tabatabaei; Yannan Lin; Denise R. Aberle; Ashley Elizabeth Prosper; William W.Y. Hsu (2025). SPIE Medical Imaging: Imaging Informatics for Healthcare, Research, and Applications

DOI 10.1117/12.3049089

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Foundation models are increasingly recognized for their ability to extract robust imaging features by learning generalized representations from large datasets of unannotated images. Foundation models show promise in generating task-agnostic features that outperform conventional methods in diagnostic and prognostic tasks. However, the clinical application of imaging biomarkers is often hampered by their sensitivity to variations in image acquisition and reconstruction parameters. Hence, we evaluated the robustness of features extracted using the pretrained foundation model from low-dose computed tomography (LDCT) scans under varying image conditions. We analyzed 59 LDCT scans containing at least one nodule from individuals who underwent lung cancer screening. Each scan consisted of 6 variations of image conditions, including combinations of three reconstruction kernels (smooth, medium, sharp) and two slice thicknesses (1.0 mm, 2.0 mm). 56 nodules had nodule outcome labels (cancer vs. non-cancer) available, of which 7 had cancer outcomes. Features were extracted using the foundation model across all image conditions. The feature-level robustness was evaluated by computing the concordance correlation coefficient (CCC) between each feature value extracted from the reference condition (Medium/1.0) and the other 5 conditions. We also examined the impact of varying image conditions on the features' predictive ability in nodule outcome classification. Pyradiomics, a well-established radiomic feature extractor, served as a baseline for comparison. The foundation model consistently yielded high mean CCC values ranging from 0.937 (Smooth/2.0) to 0.984 (Sharp/1.0), indicating robustness against variations in image conditions. Moreover, the foundation model's features demonstrated high performance in nodule outcome classification compared to Pyradiomics features. However, inconsistencies in performance across different image conditions underscore the need for further exploration of harmonization techniques and modeling strategies to enhance the generalizability and clinical utility of imaging biomarkers.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=6; title_english_share=0.3750; title_reads=english; abstract_words=277; abstract_english_function_words=81; abstract_english_share=0.2924; abstract_reads=english; language_check=metadata_listed