Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Computed tomography-guided cutting needle biopsy for lung nodules
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
Abstract We aim to compare the diagnostic accuracy, safety, and radiation exposure between low-dose and standard-dose computed tomography (CT)-guided cutting needle biopsy (CNB) for lung nodules. From January 2016 to August 2017, all consecutive patients admitted with lung nodule underwent low-dose or standard-dose CT-guided CNB procedure in our center. Diagnostic accuracy and radiation dose were compared. A total of 67 and 69 patients who underwent low-dose and standard-dose CT-guided CNB procedure were included in this study. Each patient underwent CT-guided CNB for 1 nodule. The technical success rates were 100% in both groups. The sensitivity, specificity, and overall diagnostic accuracy were 97.7%, 100%, and 98.5% for low-dose group and 91.5%, 100%, and 94.2% for standard-dose group. There was no significant difference in diagnostic accuracy (P = .380) between 2 groups. Pneumothorax was found in 8 and 15 patients in the low-dose and standard-dose groups, respectively (11.9% vs 21.7%, P = .127). Hemoptysis was found in 10 and 10 patients in the low-dose and standard-dose groups, respectively (14.9% vs 14.5%, P = .943). The mean dose-length product was 38.2 ± 17.2 mGy-cm and 375.3 ± 115.7 mGy-cm in the low-dose and standard-dose groups (P < .001). The mean dose-length product was 38.2 ± 17.2 mGy-cm and 375.3 ± 115.7 mGy-cm in the low-dose and standard-dose groups, respectively (P < .001). The mean effective dose was 0.5 ± 0.2 mSv and 5.3 ± 1.6 mSv in the low-dose and standard-dose groups, respectively (P < .001). Low-dose CT-guided CNB of lung nodules significantly decreased radiation dose compared with standard-dose CT. The low-dose protocol could provide similar diagnostic accuracy and safety as standard-dose CT-guided CNB for lung nodules.
From Crossref.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=9; title_english_function_words=1; title_english_share=0.1111; title_reads=english; abstract_words=260; abstract_english_function_words=78; abstract_english_share=0.3000; abstract_reads=english; language_check=metadata_listed