Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Computed tomography-guided cutting needle biopsy for lung nodules

Hui-Mei Zhang; Xiao-Bing Huo; Hua-Long Wang; Xiao Zhang; Yu-Fei Fu (2021). Medicine

DOI 10.1097/md.0000000000024001

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Abstract We aim to compare the diagnostic accuracy, safety, and radiation exposure between low-dose and standard-dose computed tomography (CT)-guided cutting needle biopsy (CNB) for lung nodules. From January 2016 to August 2017, all consecutive patients admitted with lung nodule underwent low-dose or standard-dose CT-guided CNB procedure in our center. Diagnostic accuracy and radiation dose were compared. A total of 67 and 69 patients who underwent low-dose and standard-dose CT-guided CNB procedure were included in this study. Each patient underwent CT-guided CNB for 1 nodule. The technical success rates were 100% in both groups. The sensitivity, specificity, and overall diagnostic accuracy were 97.7%, 100%, and 98.5% for low-dose group and 91.5%, 100%, and 94.2% for standard-dose group. There was no significant difference in diagnostic accuracy (P = .380) between 2 groups. Pneumothorax was found in 8 and 15 patients in the low-dose and standard-dose groups, respectively (11.9% vs 21.7%, P = .127). Hemoptysis was found in 10 and 10 patients in the low-dose and standard-dose groups, respectively (14.9% vs 14.5%, P = .943). The mean dose-length product was 38.2 ± 17.2 mGy-cm and 375.3 ± 115.7 mGy-cm in the low-dose and standard-dose groups (P < .001). The mean dose-length product was 38.2 ± 17.2 mGy-cm and 375.3 ± 115.7 mGy-cm in the low-dose and standard-dose groups, respectively (P < .001). The mean effective dose was 0.5 ± 0.2 mSv and 5.3 ± 1.6 mSv in the low-dose and standard-dose groups, respectively (P < .001). Low-dose CT-guided CNB of lung nodules significantly decreased radiation dose compared with standard-dose CT. The low-dose protocol could provide similar diagnostic accuracy and safety as standard-dose CT-guided CNB for lung nodules.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=1; title_english_share=0.1111; title_reads=english; abstract_words=260; abstract_english_function_words=78; abstract_english_share=0.3000; abstract_reads=english; language_check=metadata_listed