Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Automated Low-Kilovoltage Selection in Pediatric Computed Tomography Angiography

Marilyn Joy Siegel; Juan Carlos Ramirez-Giraldo; Charles Hildebolt; David Bradley; Bernhard Schmidt (2013). Investigative Radiology

DOI 10.1097/rli.0b013e318289f918

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

PURPOSE: The purpose of this study was to compare the effects of combined automated tube voltage selection and automated tube current modulation on radiation dose and image quality in small-sized phantoms undergoing computed tomography angiography (CTA) with the use of automated current modulation alone. MATERIALS AND METHODS: Three semianthropomorphic phantoms, corresponding to a neonate, a small child, and a small adult, underwent simulated abdominal CTA using an automated tube voltage selection technology, which simultaneously optimizes kilovoltage (in kilovolt [peak]) and tube-current/milliamperage (in milliampere-second) on the basis of the patient topogram and clinical task. The phantoms were scanned with 2 protocols: protocol A, using the combination of automated kilovoltage and milliamperage, and protocol B, using only automated milliamperage with the standard 120 kV(p). Radiation doses were measured for each phantom, and the measurements were then used to estimate volume computed tomography dose index. Image noise and iodine contrast, contrast-to-noise ratio, and the relative dose factor were assessed. Differences were tested using paired t tests, and percentage differences for various technical factors and the phantom sizes were calculated. RESULTS: The computed tomography dose index was significantly lower in protocol A (mean, 3.3 mGy) compared with that in protocol B (mean, 7.7 mGy), representing a 56.0% dose reduction (P = 0.01). In protocol A, tube potential dropped from 120 to 70 kV(p) in the small and medium phantoms and to 80 kV(p) in the large phantom. For each phantom size, image noise and iodine contrast increased significantly in protocol A relative to those in protocol B (P = 0.03 and P < 0.01, respectively). Corresponding contrast-to-noise ratio values increased by 9.1% in protocol A relative to those in protocol B (P = 0.04). The relative dose factor values for protocol A relative to those for protocol B were 31%, 36%, and 44% for the small, medium, and large phantoms, respectively. CONCLUSIONS: Combined use of automated kilovoltage selection and automated tube current modulation is more effective for reducing radiation dose and maintaining image quality during simulated pediatric CTA than is automated tube current modulation in isolation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=1; title_english_share=0.1111; title_reads=english; abstract_words=333; abstract_english_function_words=116; abstract_english_share=0.3483; abstract_reads=english; language_check=metadata_listed