Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diagnostic Accuracy in Detecting Fungal Infection with Ultra-Low-Dose Computed Tomography (ULD-CT) Using Filtered Back Projection (FBP) Technique in Immunocompromised Patients

Luigia D’Errico; Anita Ghali; Mini Pakkal; Micheal Chad McInnis; Hatem Mehrez; Andre C. Schuh; John G. Kuruvilla; Mark David Minden; Narinder Paul (2024). Journal of Clinical Medicine

DOI 10.3390/jcm13061704

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Purpose: To compare the accuracy of ultra-low-dose (uLDCT) to standard-of-care low-dose chest CT (LDCT) in the detection of fungal infection in immunocompromised (IC) patients. Method and Materials: One hundred IC patients had paired chest CT scans performed with LDCT followed by uLDCT. The images were independently reviewed by three chest radiologists who assessed the image quality (IQ), diagnostic confidence, and detection of major (macro nodules, halo sign, cavitation, consolidation) and minor (4–10 mm nodules, ground-glass opacity) criteria for fungal disease using a five-point Likert score. Discrepant findings were adjudicated by a fourth chest radiologist. Box–whisker plots were used to analyze IQ and diagnostic confidence. Inter-rater reliability was assessed using interclass correlation coefficients (ICCs). The statistical difference between LDCT and uLDCT results was assessed using Wilcoxon paired test. Results: Lung reconstructions had IQ and diagnostic confidence scores (mean ± std) of 4.52 ± 0.47 and 4.63 ± 0.51 for LDCT and 3.85 ± 0.77 and 4.01 ± 0.88 for uLDCT. The images were clinically acceptable except for uLDCT in obese patients (BMI ≥ 30 kg/m2), which had an IQ ranking from poor to excellent (scores 1 to 5). The accuracy in detecting major and minor radiological findings with uLDCT was 96% and 84% for all the patients. The inter-rater agreements were either moderate, good, or excellent, with ICC values of 0.51–0.96. There was no significant statistical difference between the uLDCT and LDCT ICC values (p = 0.25). The effective dose for uLDCT was one quarter that of LDCT (CTDIvol = 0.9 mGy vs. 3.7 mGy). Conclusions: Thoracic uLDCT, at a 75% dose reduction, can replace LDCT for the detection of fungal disease in IC patients with BMI < 30.0 kg/m2.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=23; title_english_function_words=3; title_english_share=0.1304; title_reads=english; abstract_words=262; abstract_english_function_words=85; abstract_english_share=0.3244; abstract_reads=english; language_check=metadata_listed