Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Pure Vision Transformer (CT-ViT) with Noise2Neighbors Interpolation for Low-Dose CT Image Denoising
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Convolutional neural networks (CNN) have been used for a wide variety of deep learning applications, especially in computer vision. For medical image processing, researchers have identified certain challenges associated with CNNs. These challenges encompass the generation of less informative features, limitations in capturing both high and low-frequency information within feature maps, and the computational cost incurred when enhancing receptive fields by deepening the network. Transformers have emerged as an approach aiming to address and overcome these specific limitations of CNNs in the context of medical image analysis. Preservation of all spatial details of medical images is necessary to ensure accurate patient diagnosis. Hence, this research introduced the use of a pure Vision Transformer (ViT) for a denoising artificial neural network for medical image processing specifically for low-dose computed tomography (LDCT) image denoising. The proposed model follows a U-Net framework that contains ViT modules with the integration of Noise2Neighbor (N2N) interpolation operation. Five different datasets containing LDCT and normal-dose CT (NDCT) image pairs were used to carry out this experiment. To test the efficacy of the proposed model, this experiment includes comparisons between the quantitative and visual results among CNN-based (BM3D, RED-CNN, DRL-E-MP), hybrid CNN-ViT-based (TED-Net), and the proposed pure ViT-based denoising model. The findings of this study showed that there is about 15-20% increase in SSIM and PSNR when using self-attention transformers than using the typical pure CNN. Visual results also showed improvements especially when it comes to showing fine structural details of CT images.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=260; abstract_english_function_words=82; abstract_english_share=0.3154; abstract_reads=english; language_check=metadata_listed