Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

P78 The role of computer-assisted radiographer reporting in lung cancer screening programmes

Helen Hall; Mamta Ruparel; Samantha L. Quaife; Jennifer L. Dickson; Carolyn Horst; Sophie Tisi; James Batty; Nick Woznitza; Asia Ahmed; Stephen J. Burke; Penny J. Shaw; MJ Soo; Magali N. Taylor; Neal Navani; Angshu Bhowmik; David Baldwin; S.W. Duffy; Arjun Nair; Anand Devaraj; Sam M. Janes (2019). Thorax

DOI 10.1136/thorax-2019-btsabstracts2019.221

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Introduction and objectives The success of lung cancer screening (LCS) with low-dose CT (LDCT) depends critically on delivering timely, accurate radiology reports. Its anticipated widespread introduction will place a significant burden on current thoracic radiologist capacity, mandating innovative solutions. We explored the role that trained radiographers, using computer-assisted nodule detection (CADe) software, might have in LCS reporting pathways. Methods 770 LDCTs performed as part of the Lung Screen Uptake trial (LSUT) were retrospectively reported by two radiographers (R1 and R2) using the Veolity™ CADe software. Radiographers could request the opinion of the study radiologist about uncertain findings. The original radiologists’ reports (read without CADe) were considered the reference standard. Studies were categorised as ‘positive’ (nodule or mass requiring nodule surveillance or MDT referral), ‘negative’ (no intrapulmonary findings requiring further imaging) or ‘ill-defined’ (indistinct focal abnormality requiring surveillance, e.g. consolidation). Reported outcomes were compared to the reference standard, with any discrepant (i.e. radiographer-only reported) nodules re-reviewed by both study radiologist and a second independent radiologist, and verified as either ‘true’ or ‘false positive’ (figure 1). Secondary outcomes included scan-reading times and identification of incidental findings. Results The reference standard dataset included 163 ‘positive’, 35 ‘ill-defined’, and 572 ‘negative’ studies, and 34 confirmed lung cancers. R1 and R2 requested radiologist confirmation for 6.5% and 10.4% of studies respectively. Following verification of discrepant nodules, reporting sensitivity varied significantly between radiographers at 67.3% (R1) and 74.0% (R2) for all ‘positive’ studies (OR 2.27, p=0.03): 77.4% and 93.9% for confirmed cancers. The majority of ‘missed’ lesions arose from inappropriate rejection of CADe-detected findings rather than being missed altogether. The radiographer plus CADe reading combination highlighted ten nodules previously dismissed by the study radiologist, that were subsequently recalled for further surveillance. Allowing for these, the rates of false positive reporting were 7.9% (R1) and 6.2% (R2). Conclusions Individual performance varied significantly between the two radiographers, but the overall results suggest inadequate sensitivity to recommend this strategy. As per previous observations elsewhere, using CADe software in LCS reporting pathways is likely to reduce reporting times whilst increasing reader sensitivity.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=337; abstract_english_function_words=95; abstract_english_share=0.2819; abstract_reads=english; language_check=metadata_listed