Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Converting dose-area product to effective dose in dental cone-beam computed tomography using organ-specific deep learning

Ruben Pauwels (2024). Dentomaxillofacial Radiology

DOI 10.1093/dmfr/twae067

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Abstract Objective To develop an accurate method for converting dose-area product (DAP) to patient dose for dental cone-beam computed tomography (CBCT) using deep learning. Methods A total of 24 384 CBCT exposures of an adult phantom were simulated with PCXMC 2.0, using permutations of tube voltage, filtration, source-isocenter distance, beam width/height, and isocenter position. Equivalent organ doses as well as DAP values were recorded. Next, using the aforementioned scan parameters as inputs, neural networks (NN) were trained using Keras for estimating the equivalent dose per DAP for each organ. Two methods were explored for positional input features: (1) “Coordinate” mode, which uses the (continuous) XYZ coordinates of the isocentre, and (2) “AP/JAW” mode, which uses the (categorical) anteroposterior and craniocaudal position. Each network was trained, validated, and tested using a 3/1/1 data split. Effective dose (ED) was calculated from the combination of NN outputs using ICRP 103 tissue weighting factors. The performance of the resulting NN models for estimating ED/DAP was compared with that of a multiple linear regression (MLR) model as well as direct conversion coefficients (CC). Results The mean absolute error (MAE) for organ dose/DAP on the test data ranged from 0.18% (bone surface) to 2.90% (oesophagus) in “Coordinate” mode and from 2.74% (red bone marrow) to 14.13% (brain) in “AP/JAW” mode. The MAE for ED was 0.23% and 4.30%, respectively, for the two modes, vs. 5.70% for the MLR model and 20.19%-32.67% for the CCs. Conclusions NNs allow for an accurate estimation of patient dose based on DAP in dental CBCT.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=2; title_english_share=0.1111; title_reads=english; abstract_words=247; abstract_english_function_words=79; abstract_english_share=0.3198; abstract_reads=english; language_check=metadata_listed