Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Determining the clinical utility of a breath test for screening an asbestos-exposed population for pleural mesothelioma: baseline results

Kathleen Zwijsen; Eline Schillebeeckx; Eline Janssens; Joris Van Cleemput; Tom Richart; Veerle F.M. Surmont; Kristiaan Nackaerts; Elly Marcq; Jan P. van Meerbeeck; Kevin Lamote (2023). Journal of Breath Research

DOI 10.1088/1752-7163/acf7e3

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Pleural mesothelioma (PM) is an aggressive cancer of the serosal lining of the thoracic cavity, predominantly caused by asbestos exposure. Due to nonspecific symptoms, PM is characterized by an advanced-stage diagnosis, resulting in a dismal prognosis. However, early diagnosis improves patient outcome. Currently, no diagnostic biomarkers or screening tools are available. Therefore, exhaled breath was explored as this can easily be obtained and contains volatile organic compounds, which are considered biomarkers for multiple (patho)physiological processes. A breath test, which differentiates asbestos-exposed (AEx) individuals from PM patients with 87% accuracy, was developed. However, before being implemented as a screening tool, the clinical utility of the test must be determined. Occupational AEx individuals underwent annual breath tests using multicapillary column/ion mobility spectrometry. A baseline breath test was taken and their individual risk of PM was estimated. PM patients were included as controls. In total, 112 AEx individuals and six PM patients were included in the first of four screening rounds. All six PM patients were correctly classified as having mesothelioma (100% sensitivity) and out of 112 AEx individuals 78 were classified by the breath-based model as PM patients (30% specificity). Given the large false positive outcome, the breath test will be repeated annually for three more consecutive years to adhere to the 'test, re-test' principle and improve the false positivity rate. A low-dose computed tomography scan in those with two consecutive positive tests will correlate test positives with radiological findings and the possible growth of a pleural tumor. Finally, the evaluation of the clinical value of a breath-based prediction model may lead to the initiation of a screening program for early detection of PM in Aex individuals, which is currently lacking. This clinical study received approval from the Antwerp University Hospital Ethics Committee (B300201837007).

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=6; title_english_share=0.3158; title_reads=english; abstract_words=294; abstract_english_function_words=103; abstract_english_share=0.3503; abstract_reads=english; language_check=metadata_listed