Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diffusion-based image translation model from low-dose chest CT to calcium scoring CT with random point sampling

Ji-Hoon Jung; Jong Eun Lee; Hyun Seo Lee; Dong Hyun Yang; June‐Goo Lee (2025). Computers in Biology and Medicine

DOI 10.1016/j.compbiomed.2025.110506

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Coronary artery calcium (CAC) scoring is an important method for cardiovascular risk assessment. While artificial intelligence (AI) has been applied to automate CAC scoring in calcium scoring computed tomography (CSCT), its application to low-dose computed tomography (LDCT) scans, typically used for lung cancer screening, remains challenging due to the lower image quality and higher noise levels of LDCT. PURPOSE: This study presents a diffusion model-based method for converting LDCT to CSCT images with the aim of improving CAC scoring accuracy from LDCT scans. METHODS: A conditional diffusion model was developed to generate CSCT images from LDCT by modifying the denoising diffusion implicit model (DDIM) sampling process. Two main modifications were introduced: (1) random pointing, a novel sampling technique that enhances the trajectory guidance methodology of DDIM using stochastic Gaussian noise to optimize domain adaptation, and (2) intermediate sampling, an advanced methodology that strategically injects minimal noise into LDCT images prior to sampling to maximize structural preservation. The model was trained on LDCT and CSCT images obtained from the same patients but acquired separately at different time points and patient positions, and validated on 37 test cases. RESULTS: The proposed method showed superior performance compared to widely used image-to-image models (CycleGAN, CUT, DCLGAN, NEGCUT) across several evaluation metrics, including peak signal-to-noise ratio (39.93 ± 0.44), Local Normalized Cross-Correlation (0.97 ± 0.01), structural similarity index (0.97 ± 0.01), and Dice similarity coefficient (0.73 ± 0.10). The modifications to the sampling process reduced the number of iterations from 1000 to 10 while maintaining image quality. Volumetric analysis indicated a stronger correlation between the calcium volumes in the enhanced CSCT images and expert-verified annotations, as compared to the original LDCT images. CONCLUSIONS: The proposed method effectively transforms LDCT images to CSCT images while preserving anatomical structures and calcium deposits. The reduction in sampling time and the improved preservation of calcium structures suggest that the method could be applicable for clinical use in cardiovascular risk assessment.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=3; title_english_share=0.1667; title_reads=english; abstract_words=313; abstract_english_function_words=91; abstract_english_share=0.2907; abstract_reads=english; language_check=metadata_listed