Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Role of low dose computed tomography in the evaluation of solitary pulmonary nodule in comparison to standard dose computed tomography

Saif Mohammed Hadi; Ahmed Dhunoon Marsool; Hawraa Emad Majeed (2026). International Journal of Radiology and Diagnostic Imaging

DOI 10.33545/26644436.2026.v9.i5a.537

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Background: A solitary pulmonary nodule (SPN) is a well-circumscribed pulmonary opacity measuring less than 3 cm without associated parenchymal, pleural, or mediastinal abnormalities. Computed tomography (CT) plays a central role in SPN evaluation through assessment of size, growth, attenuation, margins, calcification, and pleural features. However, radiation exposure remains a concern, highlighting the need for lower-dose protocols. Aim: To assess the diagnostic performance of low-dose CT compared with standard-dose CT in detecting and characterizing SPNs. Methods: This prospective study included patients referred for non-enhanced chest CT for various indications, including cough, hemoptysis, dyspnea, and follow-up of known nodules. Patients with multiple nodules or diffuse lung disease were excluded. Each patient underwent standard-dose CT (120 kV, 150 mAs) followed by low-dose CT (120 kV, 50 mAs). Two radiologists independently evaluated nodules for size, attenuation, margins, spiculation, lobulation, calcification, and pleural indentation. Statistical analysis assessed interobserver agreement and concordance between protocols. Results: Forty-eight patients (58.3% females, 41.7% males; median age 55.2 years) were included. No significant differences were observed in nodule size measurements between observers or between low-dose and standard-dose CT (p>0.05). Interobserver agreement was statistically significant across all evaluated features, ranging from substantial to almost perfect. Similarly, agreement between low-dose and standard-dose CT was substantial for margin, calcification, and attenuation, and almost perfect for spiculation, lobulation, and pleural indentation (p<0.05). Conclusion: Low-dose CT demonstrates comparable accuracy to standard-dose CT in SPN evaluation while significantly reducing radiation exposure, supporting its use as a reliable alternative imaging protocol.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=20; title_english_function_words=6; title_english_share=0.3000; title_reads=english; abstract_words=251; abstract_english_function_words=61; abstract_english_share=0.2430; abstract_reads=english; language_check=metadata_missing