Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Dose Reduction on Computed Tomography Angiography Using Adaptive Control Techniques

Zhijun Cai; Er-Wei Bai; Ge Wang (2012). Computed Tomography - Clinical Applications

DOI 10.5772/22807

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

With advent of multi-slice computed tomography (CT) scanner and sophisticated CT reconstruction algorithm, CT Angiography (CTA) is increasingly used to evaluate patient with vascular diseases (Fleischmann et al., 2006; Chow & Rubin, 2002; Rubin at al., 2001). It has many advantages over conventional catheter angiograms: 1) non-invasiveness, 2) short acquisition time, 3) multiple viewing methods, and 4) low cost. However, radiation exposure of CT scan has become of a wide concern due to its induction to genetic, cancerous and other diseases (Brenner et al., 2001; de Gonzalez & Darby et al., 2004). According to (Mettler et al., 2000), CT scan delivers 2/3 of total radiation dose every year in US, and this number is climbing. On June 19th, 2007, New York Times reported that the percapita dose of ionizing radiation from clinical imaging exams in U.S. increased almost 600% from 1980 to 2006. Brenner (Brenner et al., 2001) reported that diagnostic X-rays, indicating that radiation from medical and dental scans, cause about 700 cases of cancer per year in Britain and more than 5,600 cases in US. To that end, every effort to reduce radiation dose is appreciated and well-known ALARA (As Low As Reasonably Achievable) principle is widely accepted in medical community. There are many studies have been reported on dose reduction for CT scan. Wintersperger and his colleagues (Wintersperger et al., 2000) used lower kilo-voltage and claimed resultant image had similar sensitivity and accuracy. In Fraioli’s studies (Fraioli et al., 2006), lower tube currents were used and resultant image quality was claimed to be good enough for diagnosis. Generally, dose reduction is contrary to image quality. In other words, reducing radiation dose will sacrifice image quality. However, with advanced CT reconstruction algorithm (Yan et al., 2008; Zeng et al., 2007; Liu et al., 2009; Yin et al., 2009) and post-processing techniques (Salmon et al., 2009; Benitez et al., 2009; Zeng et al., 2008; Zhang et al., 2008), resultant images could be held to certain diagnosis level while radiation dose is reduced lot. Recently, control technique is found very useful in CT. It can be applied to improve CT image quality (Lu et al., 2008; H. Bai et al., 2008), and to reduce radiation dose reduction, for example, Automatic Exposure Control (AEC) program, which modulates tube current to maintain same x-ray attenuation level according to scan angle/position of human body.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=10; title_english_function_words=1; title_english_share=0.1000; title_reads=english; abstract_words=369; abstract_english_function_words=104; abstract_english_share=0.2818; abstract_reads=english; language_check=metadata_listed