Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose CT noise reduction based on local total variation and improved wavelet residual CNN

Yi Liu; Jiaqi Kang; Zhiyuan Li; Quan Zhang; Zhiguo Gui (2022). Journal of X-Ray Science and Technology

DOI 10.3233/xst-221233

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low-dose computed tomography (LDCT) is an effective method for reducing radiation exposure. However, reducing radiation dose leads to considerable noise in the reconstructed image that can affect doctor's judgment. OBJECTIVE: To solve this problem, this study proposes a local total variation and improved wavelet residual convolutional neural network (LTV-WRCNN) denoising model. METHODS: The model first introduces local total variation (LTV) to decompose the LDCT image into cartoon and texture image. Next, the texture image is filtered using the non-local mean (NLM). Then, the cartoon image is added to the filtered texture image to obtain the preprocessing image. Finally, the pre-processed image is fed into the improved wavelet residual neural network (WRCNN) to obtain an improved image. Additionally, we also introduce a compound loss in wavelet domain that combines mean squared error loss and directional regularization loss to separate the structural details from noise more thoroughly. RESULTS: Compared with state-of-the-art methods, the peak-signal-to-noise ratio (PSNR) value and the structure similarity (SSIM) value of the processed CT images using the new proposed model are 33.4229 dB and 0.9158. Study also shows that applying new model obtains better results visually and numerically, especially in terms of the preservation of structural details. CONCLUSIONS: The proposed new model is feasible and effective in improving the quality of LDCT images.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=224; abstract_english_function_words=69; abstract_english_share=0.3080; abstract_reads=english; language_check=metadata_listed