Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Multidimensional LDCT Imaging Endpoints for an Early-Phase Trial of Curcumin and Omega-3 Fatty Acids for Lung Cancer Chemoprevention: Results of a Randomized Pilot Trial
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
Former smokers in lung cancer screening remain at elevated risk for lung cancer despite smoking cessation. We and others have shown that curcumin exhibits anti-inflammatory and antiproliferative effects but is limited by poor bioavailability. However, since curcumin is lipophilic, co-administration with omega-3 fatty acids (ω-3 ω-3 ω-3 FA) represents a mechanistically rational strategy to enhance delivery and target complementary pathways, including STAT3 and NF-κB signaling for lung cancer chemoprevention. Methods: We conducted a randomized, single-blind, placebo-controlled pilot study evaluating curcumin combined with ω-3 FA in high-risk former and current smokers with CT-detected pulmonary nodules. Participants received intervention agents or placebo for 6 months. Primary endpoints included radiologic changes in nodule size, number, and density. Secondary endpoints included safety, adherence, bioavailability, and exploratory biomarker analyses. Correlation analyses of imaging-derived metrics were performed to assess relationships among LDCT parameters. Results: Nineteen participants were enrolled (intervention, n=12; placebo, n=7). No statistically significant between-group differences were observed in primary imaging endpoints. The intervention was well tolerated, with predominantly grade 1 adverse events. Exploratory analyses demonstrated consistent positive correlations among LDCT-derived measures, with clustering of size-based metrics (mean diameter, volume, sum of longest diameters) and density-based parameters. Multidimensional scaling supported this structure, indicating internal coherence among imaging-derived endpoints. Conclusions: Although no statistically significant treatment effect on the image biomarkers was observed, this pilot study demonstrates feasibility challenges and identifies coherent imaging biomarkers that may serve as intermediate endpoints in early-phase chemoprevention trials. These results support further investigation of strategies utilizing agent combinations with enhanced bioavailability and safety and refinement of trial design in high-risk lung cancer patient populations.
From Crossref.
The criteria
-
Include if: The document is in English.
Unclear (checked by an automatic rule)What the rule found: language_in: language=; title_words=25; title_english_function_words=7; title_english_share=0.2800; title_reads=english; abstract_words=276; abstract_english_function_words=64; abstract_english_share=0.2319; abstract_reads=english; language_check=metadata_missing