Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A hybrid metaheuristic-GAN approach for automated low-dose CT image enhancement

Ali Abdulazeez Mohammed Baqer Qazzaz (2026). Franklin Open

DOI 10.1016/j.fraope.2026.100549

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Enhancing Low-Dose Computed Tomography (LDCT) images is a crucial task in medical imaging, aimed at mitigating the inherent noise and artifacts that compromise diagnostic accuracy while preserving the benefits of reduced patient radiation exposure. This research introduces a novel hybrid intelligence model that achieves a state-of-the-art enhancement by automating the complex design and optimization process of a deep learning model. The proposed methodology pioneers a unique cooperation between metaheuristics and deep generative networks; the model employs Particle Swarm Optimization (PSO) to intelligently search a multi-dimensional hyperparameter space, discovering the optimal learning rate, loss function weights, and a baseline CLAHE parameter for a custom Generative Adversarial Network (GAN). The GAN generator is a U-Net architecture that learns a residual correction, which is additively combined with the CLAHE-processed image to leverage the strengths of both classical and deep learning techniques. The framework was extensively trained for 200 epochs on 400 paired images from the public AAPM Low Dose CT Grand Challenge dataset. On an unseen test set, the final model demonstrated remarkable improvements, significantly increasing the Structural Similarity Index (SSIM) from approximately 0.8910 to 0.9306 and drastically reducing the perceptual LPIPS error from about 0.0948 to an exceptional 0.0442, while improving the NIQE score. By successfully bridging metaheuristic search with a sophisticated GAN architecture, this work presents a robust, automated, and highly effective approach that outperforms the baseline LDCT quality across key perceptual and structural metrics, providing a valuable blueprint for future high-fidelity medical image enhancement systems.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=247; abstract_english_function_words=79; abstract_english_share=0.3198; abstract_reads=english; language_check=metadata_listed