Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Reproducibility of radiomic features of pulmonary nodules between low-dose CT and conventional-dose CT

Yufan Gao; Minghui Hua; Jun Lv; Yanhe Ma; Yanzhen Liu; Min Ren; Yaohua Tian; Ximing Li; Hong Zhang (2022). Quantitative Imaging in Medicine and Surgery

DOI 10.21037/qims-21-609

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background: The reproducibility of radiomic features is essential to lung cancer detection. This study aimed to investigate the reproducibility of radiomic features of pulmonary nodules between low-dose computed tomography (LDCT) and conventional-dose computed tomography (CDCT). Methods: A total of 105 patients with 119 pulmonary nodules [39 ground-glass nodules (GGNs) and 80 solid nodules] who underwent LDCT and CDCT were retrospectively studied between September 2019 and November 2020. Pulmonary nodules were manually segmented and 1,125 radiomic features (shape, first-order intensity, texture, wavelet, and Laplacian of the Gaussian features) were extracted from both LDCT and CDCT images. The concordance correlation coefficient (CCC) was used to evaluate the reproducibility of these radiomic features. Results: Of the 1,125 radiomic features considered, 35.5% (399 of 1,125) and 41.5% (467 of 1,125) were reproducible (CCC ≥0.85) for GGNs and solid nodules, respectively. The intensity, texture, and wavelet features of solid nodules were more reproducible than those of GGNs. The mean CCC values for intensity and texture features of solid nodules were of 0.85 and above, whereas the mean values for those of GGNs were of less than 0.85. After Gaussian kernel (σ =2) preprocessing, the CCC of intensity and texture features of GGNs improved from 0.77 to 0.90, and 84.9% (79 of 93) of the radiomic features were reproducible (mean CCC increase from 0.84±0.13 to 0.92±0.08 for intensity features, and from 0.75±0.15 to 0.89±0.11 for texture features). Wavelet features had the lowest CCCs for both GGNs and solid nodules. Conclusions: The majority of the radiomic feature classes of solid pulmonary nodules have a high level of reproducibility between LDCT and CDCT. However, LDCT should not be used as an alternative to CDCT in the radiomic study of GGNs.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=4; title_english_share=0.2667; title_reads=english; abstract_words=259; abstract_english_function_words=110; abstract_english_share=0.4247; abstract_reads=english; language_check=metadata_listed