Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A quality improvement method for lung LDCT images

Yang Chen; Xiaoting Dai; Huihong Duan; Lei Gao; Xiwen Sun; Shengdong Nie (2020). Journal of X-Ray Science and Technology

DOI 10.3233/xst-190605

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low dose computed tomography (LDCT) reduces radiation damage to patients. However, with the decrease of radiation dose, LDCT images of the lung often appear some serious problems such as poor contrast, noise and streak artifacts. OBJECTIVE: To improve the quality of lung LDCT images, this study proposed and investigated a new denoising method based on classification training structure combined dictionary for lung LDCT images. METHODS: First, top-hat transform and anisotropic diffusion with a shock filter (ADSF) algorithm are used to enhance the image contrast and image details. Second, an adaptive dictionary is trained and used for noise reduction. Third, more image details are extracted from the residual image by using the atom activity measurement. The final result is obtained by combining the dictionary denoising result with the extracted detail information. The proposed method is then validated by both simulated and clinical lung LDCT images. Four metrics including Contrast-to-Noise Ratio (CNR), Noise Suppression Index (NSI), Edge Preserving Index (EPI), and Blurring Index (BI) are computed to quantitatively evaluate image quality. RESULTS: The results showed that the CNR, NSI, EPI, and BI of our method reached 8.953, 0.9500, 0.7230 and 0.0170, respectively. Noise and streak artifacts can be removed from lung LDCT images while keeping and retaining more details. CONCLUSIONS: Comparing with the results of other methods tested using the same dataset, this study demonstrated that our new method significantly improved quality of the lung LDCT images.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=8; title_english_function_words=2; title_english_share=0.2500; title_reads=english; abstract_words=235; abstract_english_function_words=76; abstract_english_share=0.3234; abstract_reads=english; language_check=metadata_listed