Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Evaluation of central venous stenosis using the lateral thoracic pathway on low-dose CT
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Objective: Collateral circulation is a biomarker of central venous stenosis (CVS). We attempted to identify the presence of CVS in hemodialysis patients using the lateral thoracic pathway (LTP) on low-dose computed tomography (CT). Methods: A total of 355 patients with end-stage renal disease were retrospectively enrolled in this study and further divided into three subgroups (central vein catheters, CVC, 121; arteriovenous fistulas, AVF, 162; and arteriovenous grafts, AVG, 72). All patients underwent low-dose CT within 10 days prior to the intervention, and CT venography was used for demonstration if it was performed during this period. Patients were defined as positive LTP when vascular-like attenuation was present on either side of the anterolateral chest wall. The incidence of thoracic varices from physical examination and LTP on low-dose CT was calculated, and their sensitivity, specificity, positive predictive value, and negative predictive value for differentiating CVS were analyzed. Results: < 0.001). In all groups, the sensitivity of LTP was significantly higher than that of the thoracic varices (CVC:0.939 vs. 0.303; AVF:0.956 vs. 0.400; AVG:0.917 vs. 0.208) and maintained a high negative predictive value (CVC:0.966; AVF:0.974; AVG:0.926). The Cohen's kappa values showed excellent reproducibility between the two radiologists (κ = 0.977). Conclusion: Negative LTP help identify hemodialysis patients at lower risk of CVS and may reduce unnecessary interventions.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=208; abstract_english_function_words=67; abstract_english_share=0.3221; abstract_reads=english; language_check=metadata_listed