Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Analysis of the baseline performance of five UK lung cancer screening programmes
Include AI
Meets all 2 topic criteria
- Decided by
- The AI (Claude Haiku 4.5)
- Basis
- Abstract
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
INTRODUCTION: Low-dose CT (LDCT) screening reduces lung cancer specific mortality. Several countries, including the UK, are evaluating the clinical impact and cost-effectiveness of LDCT screening using the latest evidence. In this paper we report baseline screening performance from five UK-based lung cancer screening programmes. METHODS: Data was collected at baseline from each screening programme. Measures of performance included prevalence of screen detected lung cancer, rate of surveillance imaging for indeterminate findings and surgical resection rates. Screening related harms were assessed by measuring false positive rates, number of invasive tests with associated complications in individuals without lung cancer and benign surgical resection rates. RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020). Overall, 84.7% (n = 9,440) of baseline LDCT scans were categorised as negative, 11.1% (n = 1,239) as indeterminate and 4.2% (n = 469) as positive. The prevalence of screen detected lung cancer was 2.2%, ranging between 1.8% and 4.4% for individual programmes. The surgical resection rate was 66% (range 46% to 83%) and post-surgical 90-day mortality for those with lung cancer 1.2% (n = 2/165). The false positive rate was 2% (n = 219/10,898) and of those with a positive result, one in two had lung cancer diagnosed (53.3%). An invasive test was required in 0.6% (n = 61/10,898) of screening attendees without lung cancer; there were no associated major complications or deaths. The benign surgical resection rate was 4.6% (n = 8/173), equating to 0.07% of the screened population. DISCUSSION: The performance of UK-based lung cancer screening programmes, delivered within or aligned to the National Health Service, compares favourably to published clinical trial data. Reported harms, including false positive and benign surgical resection rates are low. Ongoing monitoring of screening performance is vital to ensure standards are maintained and harms minimised.
From PubMed.
The criteria
-
Include if: The study presents original human clinical data on low-dose computed tomography screening for lung cancer.
Meets AIFrom the abstract: In this paper we report baseline screening performance from five UK-based lung cancer screening programmes.
From the abstract: RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020).
From the abstract: The prevalence of screen detected lung cancer was 2.2%, ranging between 1.8% and 4.4% for individual programmes.
From the abstract: The surgical resection rate was 66% (range 46% to 83%) and post-surgical 90-day mortality for those with lung cancer 1.2% (n = 2/165).
-
Include if: The study reports outcomes related to mortality, survival, early detection, illness, or disability in screened populations.
Meets AIFrom the abstract: Measures of performance included prevalence of screen detected lung cancer, rate of surveillance imaging for indeterminate findings and surgical resection rates.
From the abstract: The prevalence of screen detected lung cancer was 2.2%, ranging between 1.8% and 4.4% for individual programmes.
From the abstract: The surgical resection rate was 66% (range 46% to 83%) and post-surgical 90-day mortality for those with lung cancer 1.2% (n = 2/165).
From the abstract: The false positive rate was 2% (n = 219/10,898) and of those with a positive result, one in two had lung cancer diagnosed (53.3%).
From the abstract: An invasive test was required in 0.6% (n = 61/10,898) of screening attendees without lung cancer; there were no associated major complications or deaths.
From the abstract: The benign surgical resection rate was 4.6% (n = 8/173), equating to 0.07% of the screened population.
-
Exclude if: Abstracts or meeting presentations.
Does not apply AIFrom the record details: Source: OpenAlex; Type: article; Venue: Lung Cancer; Date: 2021-09-20; Language: en; Host: doi.org; Abstract source: PubMed
-
Exclude if: Review articles or opinion pieces.
Does not apply AIFrom the abstract: In this paper we report baseline screening performance from five UK-based lung cancer screening programmes.
From the abstract: METHODS: Data was collected at baseline from each screening programme.
From the abstract: RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020).
-
Exclude if: Animal studies or laboratory experiments.
Does not apply AIFrom the abstract: RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020).
From the abstract: In this paper we report baseline screening performance from five UK-based lung cancer screening programmes.
-
Exclude if: Studies on emphysema or asbestos exposure.
Does not apply AIFrom the title: Analysis of the baseline performance of five UK lung cancer screening programmes
From the abstract: INTRODUCTION: Low-dose CT (LDCT) screening reduces lung cancer specific mortality.
-
Exclude if: Cost-effectiveness analyses or economic evaluations.
Does not apply AIFrom the abstract: Measures of performance included prevalence of screen detected lung cancer, rate of surveillance imaging for indeterminate findings and surgical resection rates.
From the abstract: Screening related harms were assessed by measuring false positive rates, number of invasive tests with associated complications in individuals without lung cancer and benign surgical resection rates.
-
Exclude if: Microsimulation or mechanistic modeling studies.
Does not apply AIFrom the abstract: METHODS: Data was collected at baseline from each screening programme.
From the abstract: RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020).
-
Exclude if: Studies with fewer than 10 cases.
Does not apply AIFrom the abstract: RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020).
From the abstract: Overall, 84.7% (n = 9,440) of baseline LDCT scans were categorised as negative, 11.1% (n = 1,239) as indeterminate and 4.2% (n = 469) as positive.
-
Exclude if: Studies not involving human subjects.
Does not apply AIFrom the abstract: RESULTS: A total of 11,148 individuals had a baseline LDCT scan during the period of analysis (2011 to 2020).
From the abstract: In this paper we report baseline screening performance from five UK-based lung cancer screening programmes.
-
Exclude if: Non-English language publications.
Does not apply AIFrom the record details: Source: OpenAlex; Type: article; Venue: Lung Cancer; Date: 2021-09-20; Language: en; Host: doi.org; Abstract source: PubMed
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=12; title_english_function_words=3; title_english_share=0.2500; title_reads=english; abstract_words=277; abstract_english_function_words=89; abstract_english_share=0.3213; abstract_reads=english; language_check=metadata_listed
Each quote is copied word for word from the text the AI read, and checked against it by code.