Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Wavelet-domain frequency-mixing transformer unfolding network for low-dose computed tomography image denoising
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background: Low-dose computed tomography (LDCT) has become clinically essential for reducing radiation risks, but image noise remains a major challenge. Although deep learning methods have shown promise in denoising, they often fail to preserve fine structures while suppressing noise, particularly in orthopedic imaging where subtle bone textures are diagnostically critical. This study aimed to develop a wavelet-domain frequency-mixing transformer (FMT) network that simultaneously addresses noise suppression and structural preservation in orthopedic LDCT images, overcoming the limitations of current spatial-domain methods. Methods: We developed a novel unfolding network integrating (I) multiscale wavelet decomposition for frequency band-specific processing; (II) FMT blocks for cross-band feature interaction; and (III) physics-based noise modeling for realistic denoising. The model was trained and validated with clinical orthopedic scans from medical centers, with quantitative evaluation according to peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). Results: Our method achieved superior performance compared to six state-of-the-art approaches, with a mean PSNR of 42.3 dB (improvement of 3.7 dB over baseline) and an SSIM of 0.961 on the test data. Clinical evaluation by three radiologists confirmed the significantly better preservation of trabecular bone patterns (P<0.01). Conclusions: The proposed network establishes a new paradigm for LDCT denoising by explicitly modeling frequency-domain characteristics, demonstrating particular value for orthopedic applications requiring fine structural fidelity. This approach may enable further dose reduction in musculoskeletal imaging without compromising diagnostic quality.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=1; title_english_share=0.0714; title_reads=not_english; abstract_words=236; abstract_english_function_words=61; abstract_english_share=0.2585; abstract_reads=english; language_check=metadata_listed