Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Patient size matters: Effect of tube current modulation on size‐specific dose estimates (SSDE) and image quality in low‐dose lung cancer screening CT

Izabella L. Barreto; Nupur Verma; Nathan Quails; Catherine Olguín; Nathalie Correa; Tan-Lucien H. Mohammed (2020). Journal of Applied Clinical Medical Physics

DOI 10.1002/acm2.12857

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Purpose We compare the effect of tube current modulation (TCM) and fixed tube current (FTC) on size‐specific dose estimates (SSDE) and image quality in lung cancer screening with low‐dose CT (LDCT) for patients of all sizes. Methods Initially, 107 lung screening examinations were performed using FTC, which satisfied the Centers for Medicare & Medicaid Services' volumetric CT dose index (CTDI vol ) limit of 3.0 mGy for standard‐sized patients. Following protocol modification, 287 examinations were performed using TCM. Patient size and examination parameters were collected and water‐equivalent diameter ( D w ) and SSDE were determined for each patient. Regression models were used to correlate CTDI vol and SSDE with D w . Objective and subjective image quality were measured in 20 patients who had consecutive annual screenings with both FTC and TCM. Results CTDI vol was 2.3 mGy for all FTC scans and increased exponentially with D w (range = 0.96–4.50 mGy, R 2 = 0.73) for TCM scans. As patient D w increased, SSDE decreased for FTC examinations (R 2 = 1) and increased for TCM examinations (R 2 = 0.54). Image quality measurements were superior with FTC for smaller sized patients and with TCM for larger sized patients (R 2 > 0.5, P < 0.005). Radiologist graded all images acceptable for diagnostic evaluation of lung cancer screening. Conclusion Although FTC protocol offered a consistently low CTDI vol for all patients, it yielded unnecessarily high SSDE for small patients and increased image noise for large patients. Lung cancer screening with LDCT using TCM produces radiation doses that are appropriately reduced for small patients and increased for large patients with diagnostic image quality for all patients.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=24; title_english_function_words=4; title_english_share=0.1667; title_reads=english; abstract_words=256; abstract_english_function_words=72; abstract_english_share=0.2812; abstract_reads=english; language_check=metadata_listed