Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Feasibility of Sub-milliSievert Low-dose Computed Tomography with Deep Learning Image Reconstruction in Evaluating Pulmonary Subsolid Nodules: A Prospective Intra-individual Comparison Study
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
RATIONALE AND OBJECTIVES: To comprehensively assess the feasibility of low-dose computed tomography (LDCT) using deep learning image reconstruction (DLIR) for evaluating pulmonary subsolid nodules, which are challenging due to their susceptibility to noise. MATERIALS AND METHODS: Patients undergoing both standard-dose CT (SDCT) and LDCT between March and June 2023 were prospectively enrolled. LDCT images were reconstructed with high-strength DLIR (DLIR-H), medium-strength DLIR (DLIR-M), adaptive statistical iterative reconstruction-V level 50% (ASIR-V-50%), and filtered back projection (FBP); SDCT with FBP as the reference standard. Objective assessment, including image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR), and subjective assessment using five-point scales by five radiologists were performed. Detection and false-positive rate of subsolid nodules, and morphologic features of nodules were recorded. RESULTS: 102 patients (mean age, 57.0 ± 12.3 years) with 358 subsolid nodules in SDCT were enrolled. The mean effective dose of SDCT and LDCT were 5.37 ± 0.80mSv and 0.86 ± 0.14mSv, respectively (P < 0.001). DLIR-H showed the lowest noise, highest CNRs, SNRs, and subjective scores among LDCT groups (all P < 0.001), almost approaching comparability with SDCT. The detection rates for DLIR-H, DLIR-M, ASIR-V-50%, and FBP were 76.5%, 76.3%, 83.8%, and 72.1%, respectively (P < 0.001), with false-positive rate of 2.5%, 2.2%, 8.3%, and 1.1%, respectively (P < 0.001). DLIR-H showed the highest detection rates for morphologic features (79.4%-95.2%) compared to DLIR-M (74.6%-88.9%), ASIR-V-50% (72.0%-88.4%), and FBP (66.1%-84.1%) (all P ≤ 0.001). CONCLUSION: Sub-milliSievert LDCT with DLIR-H offers substantial dose reduction without compromising image quality. It is promising for evaluating subsolid nodules with a high detection rate and better identification of morphologic features.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=24; title_english_function_words=4; title_english_share=0.1667; title_reads=english; abstract_words=256; abstract_english_function_words=68; abstract_english_share=0.2656; abstract_reads=english; language_check=metadata_listed