Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Impact of filter convolution and displayed field of view on estimation of coronary Agatston scores in low-dose lung computed tomography

Yung‐Liang Wan; Pei‐Kwei Tsay; Patricia Wanping Wu; Yu‐Hsiang Juan; Hui‐Yu Tsai; Chung‐Yin Lin; Chih-Sheng Yeh; Chun‐Hua Wang; Chun‐Chi Chen (2017). International Journal of Cardiology

DOI 10.1016/j.ijcard.2017.02.124

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Coronary artery calcification (CAC) may be quantified on low-dose computed tomography (CT) of the lung (LDCT). This study aims to evaluate the effects of filter convolution (FC) and displayed field of view (dFOV) in a Toshiba 320-row CT scanner in quantifying CAC, and to compare the CAC scores obtained by LDCT with standard cardiac CT. METHODS: Fifty subjects (52 to 85years, mean 68.5, 36 males) with visible CAC underwent both standard cardiac CT and LDCT. CAC scores were obtained from standard cardiac CT using conventional FC12(22) (FC12 with 22-cm dFOV) and four different LDCT protocols: FC02(22), FC02(40), FC08(22), and FC08(40). CAC scores obtained by each LDCT protocol were compared with those obtained by standard cardiac CT. RESULTS: CAC scores obtained by all four LDCT protocols were well correlated with those by standard protocol (Pearson's coefficient=0.978 to 0.987, p<0.001; kappa=0.731 to 0.836, p<0.001). CAC scores obtained by FC08(22) showed the best agreement with standard cardiac CT (kappa=0.836, p<0.001). Under fixed dFOV, CAC scores in FC08 were significantly higher than in FC02 (p<0.001). Under fixed FC, CAC scores were significantly higher in 22-cm dFOV than in 40-cm dFOV (p≤0.006). CONCLUSIONS: Both FC and dFOV have significant impact on CAC scoring. To obtain reliable data, consistent parameters should be employed when quantifying CAC using LDCT. In a Toshiba 320-row CT scanner, CAC scores obtained by FC08(22) agree well with standard cardiac CT.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=6; title_english_share=0.2857; title_reads=english; abstract_words=227; abstract_english_function_words=67; abstract_english_share=0.2952; abstract_reads=english; language_check=metadata_listed