Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State Regulation
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Diffusion models have become a strong prior for low-dose computed tomography (LDCT) restoration. However, existing samplers apply one structure-detail trade-off to the whole image, set the restoration emphasis of each step by the timestep, and derive each next state recursively from the current one, carrying its errors forward. We propose RouteDiff, a state-aware dual-route diffusion framework that routes detail to where it can be trusted, regulates each reverse step by the state it has reached, and re-enters the trajectory from an anchored estimate. Fidelity-Refinement Routing (FRR) equips one shared U-Net with a conservative fidelity route and a detail-oriented refinement route, fuses them pixel-wise with a confidence map, and exposes their disagreement as route evidence. Hypergraph State Regulation (HSR) organizes the current features and this evidence into a state hypergraph, whose soft hyperedges group scattered regions in the same state. Its readout yields an ordered stage judgment that modulates the bottleneck, and its incidence guides feature interaction in the skip connections. Estimate-Anchored Re-entry (EAR) re-projects a route-aware anchor onto the trajectory at a fixed step and hands the new state back to HSR to be judged again. With the ten network evaluations of its baseline, RouteDiff achieves the best peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) on four datasets with inserted, real and simulated noise (40.95 dB and 95.13% on Mayo 2020; 45.18 dB and 97.23% on Mayo 2016). It also generalizes to unseen doses of real scans and yields the highest Dice (80.92%) in downstream segmentation.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=13; title_english_function_words=1; title_english_share=0.0769; title_reads=not_english; abstract_words=257; abstract_english_function_words=89; abstract_english_share=0.3463; abstract_reads=english; language_check=metadata_listed