Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A deep-learning system for automatic detection of osteoporotic vertebral compression fractures at thoracolumbar junction using low-dose computed tomography images

Xinyi Niu; Wenming Yan; Xinyu Li; Yilin Huang; Jiwu Chen; Guangrui Mu; Jianying Li; Xijun Jiao; Zhifu Zhao; Wenfeng Jing; Jianxin Guo (2022). Research Square

DOI 10.21203/rs.3.rs-2260322/v1

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Purpose: To develop a deep-learning system for automatic osteoporotic vertebral compression fractures (OVCF) detection at the thoracolumbar junction using low-dose computed tomography (CT) images. Materials and methods: 500 individuals were enrolled in this retrospective study, including 270 normal and 230 OVCF cases. The cases were divided into the training, validation, and test sets in the ratio of 6:2:2. First, a localization model using Faster R-CNN was trained to identify and locate the target thoracolumbar junction, then a 3D AnatomyNet model was trained to finely segment the target vertebrae in the localized image. Finally, 3D DenseNet model was applied for detecting OVCF on target vertebrae. Manual annotation by experienced radiologists and a clinically made diagnosis of OVCF were used as the gold standards. The performance of the detecting system was evaluated through the area under the curve (AUC) for receiver operating characteristic (ROC) analysis, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV). Results Our automated segmentation method achieved a mean Dice coefficient of 0.95 for vertebral bodies (T12-L2) segmentation on the testing dataset, with dice coefficients greater than 0.9 accounting for 96.6%. For the diagnostic performance of our system for OVCF, the AUC, sensitivity, specificity, PPV and NPV for the four-fold cross-validation on the testing dataset were 98.1%, 95.7%, 92.6%, 91.7% and 96.2%, respectively. Conclusions A deep-learning system has been developed to automatically segment vertebral bodies and accurately detect OVCF using low-dose CT.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=4; title_english_share=0.1905; title_reads=english; abstract_words=231; abstract_english_function_words=76; abstract_english_share=0.3290; abstract_reads=english; language_check=metadata_listed