Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Efficacy of computer-aided diagnosis in lung cancer screening with low-dose spiral computed tomography: receiver operating characteristic analysis of radiologists’ performance

Suzushi Kusano; Toru Nakagawa; Takatoshi Aoki; Takeshi Nawa; Kuniyoshi Nakashima; Yoshihiro Goto; Yukunori Korogi (2010). Japanese Journal of Radiology

DOI 10.1007/s11604-010-0486-1

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: The aim of this study was to evaluate the efficacy of a computer-aided diagnosis (CAD) system we developed that can also respond to subsolid nodules, for lung cancer screening using low-dose spiral computed tomography (LDCT). MATERIALS AND METHODS: The institutional review board approved this study. A total of 30 positive cases (including 15 lung cancer cases) that needed further examination and 30 negative cases were used for the observer performance study. Three thoracic radiologists, five general radiologists, and three residents participated in this study in which they first read the original CT image on its own and then reassessed the same image with the assistance of CAD. Radiologists' performance was evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The Az values without and with CAD were 0.872 and 0.910 for the thoracic radiologists, 0.864 and 0.924 for general radiologists, and 0.875 and 0.837 for residents, respectively. The detection accuracy improved significantly for the thoracic and general radiologists with our CAD system; however, no statistically significant difference between without or with CAD was seen for residents. CONCLUSION: This CAD system is beneficial in the detection of pulmonary nodules on LDCT when used by experienced radiologists.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=22; title_english_function_words=4; title_english_share=0.1818; title_reads=english; abstract_words=188; abstract_english_function_words=73; abstract_english_share=0.3883; abstract_reads=english; language_check=metadata_listed