Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Is ultra low-dose CT with tin filtration useful for examination of SI joints? Can it replace X-ray in diagnostics of sacroiliitis?

Eva Korčáková; Jana Štěpánková; David Suchy; Petr Hošek; Kristýna Bajcurová; Jan Pernický; Hynek Mírka (2021). Biomedical Papers

DOI 10.5507/bp.2021.008

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: The first objective of our study was to determine the radiation exposure received by patients during tin-filtrated ultra-low-dose computed tomography (TFULDCT) of sacroiliac joints and to compare those to conventional X-ray doses. For comparison, we added a cohort examined by low-dose CT (LDCT) without tin filtration. The second objective was to compare the results of TFULDCT and X-ray in the detection of sacroiliitis. METHODS: Our retrospective study covered 45 patients, who were examined for suspected axial spondyloarthritis (AxSpA). The first group underwent TFULDCT as well as conventional radiography (CR); the second group underwent LDCT only without tin filtration. Effective doses of TFULDCT, LDCT and CR were calculated by an experienced medical physicist. TFULDCT and CR were independently evaluated by three investigators, who decided on the presence or absence of rheumatoid inflammatory bone changes. The results were statistically evaluated. RESULTS: In our cohort, the median effective dose for TFULDCT was 0.11 mSv, range (0.06-0.40 mSv), for LDCT 0.5 mSv (0.29-0.89 mSv), and for CR 0.25 mSv (0.06-1.87 mSv). We proved that TFULDCT produces a significantly lower percentage of uncertain results (23.3%; 95% CI: 11.3-41.6%) than CR (66.7%; 95% CI: 48.3-81.1%). CONCLUSIONS: Tin filtration helps to reduce CT radiation exposure to values lower than those resulting from CR. TFULDCT offers better overall diagnostic performance than CR. Our results prove that TFULDCT can replace CR in the diagnosis of sacroiliitis in the radiographical stage of AxSpA.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=23; title_english_function_words=8; title_english_share=0.3478; title_reads=english; abstract_words=227; abstract_english_function_words=78; abstract_english_share=0.3436; abstract_reads=english; language_check=metadata_listed