Three approaches for determining imaging dose during intrafractional cone beam computed tomography in radiotherapy

(2026). Book of Abstracts - RAD 2026 Conference

DOI 10.21175/rad.abstr.book.2026.34.3

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Purpose: One of the parameters monitored during teleradiotherapy is patient positioning and internal organs motion. Pre- and post-treatment cone beam computed tomography (CBCT) is typically performed for this purpose. Intrafractional CBCT (intraCBCT) allows for the assessment of set-up variations simultaneously with irradiation. Introducing intraCBCT into clinical routine requires comparing it with standard CBCT. To this end, the computed tomography dose index (CTDI) is measured. This work proposes CTDI measurement paths for intraCBCT and the corresponding ranges of variability of CTDI values for intraCBCT (CTDIintra) compared to CTDI for CBCT (CTDICBCT). Methods: CTDI determination was performed in accordance with IAEA recommendations [1]. Measurements were taken for the chest preset on two Elekta Versa HD linacs: V1 and V2. During CTDIintra determination, the dose rate (DR(ß)) was recorded at 0.5 second intervals for a full rotation (the angle ß ranges from 0 to 360 degrees) at constant gantry speed. DR(ß) measurements were performed under the following conditions: in a phantom (DR_r(ß)) and in air (DR_ra(ß)), both for a 20mm beam width, and in air for a standard beam (DR_a(ß)). Using a proprietary program, gantry angles (ß) and times corresponding to DR(ß) were extracted from the system files. For each angle ß with an accuracy of 1°, DR(ß) was determined. CTDIintra was determined for five plans with energies of 6MV and 6FFF, and MU (monitor unit) ranging from 264.3 to 3920.5. For the selected beam, the angles ß which the kilovolt beam was exposed were extracted from the system file for each plan. Additionally, CTDIintra was calculated for five plans in the treatment and QA modes. For two plans, the measurements were repeated 10 times (once daily) and 3 times a day. The results were compared with the CTDICBCT for both linacs. Results: CTDIintra compared to CTDICBCT varied from 5.6% to 7.1% for V1 and from 10.8% to 15.4% for V2. All CTDIintra values were higher than CTDICBCT. CTDIintra values performed in the treatment mode and in the QA mode did not differ by more than 1% for both linacs. The CTDIintra value for all plans did not change by more than 0.6% for measurements 10 times once a day and 3 times a day. The difference between CTDICBCT for V1 compared to V2 was 12%. Conclusion: The performed measurements made it possible to propose three approaches for determining CTDIintra with defined variability ranges. Path 1: Performing CTDIintra measurements for a set of typical plans enables determination of CTDIintra with variation of less than 16% for a single intraCBCT compared to CTDICBCT. This result is comparable to difference between CTDICBCT for twin machines. Path 2: Performing a CTDIintra measurement for a single plan in QA mode allows assuming a CTDIintra variation of less than 2% compared to CTDICBCT. This takes into account the variability resulting from the measurement in QA mode and occurring in subsequent fractions. Path 3: Performing a measurement in treatment mode allows for determining a CTDIintra with a variability of less than 1%, which results from the variability of CTDI during subsequent fractions. Presented values may differ for different linac machines, but the research carried out allows for the selection of a course of action in order to adopt the appropriate procedure.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=520; abstract_english_function_words=210; abstract_english_share=0.4038; abstract_reads=english; language_check=metadata_missing