Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDIvol)

Anders Svensson; Jonas Björk; Kerstin Cederlund; Peter Aspelin; Ulf Nyman; Torkel B. Brismar (2014). European Radiology

DOI 10.1007/s00330-014-3220-z

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

PURPOSE: To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index CTDI(vol)) and body weight (BW). MATERIAL AND METHODS: One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI(vol) presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. RESULTS: Liver parenchymal enhancement was negatively correlated to both CTDI(vol) (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CONCLUSION: CTDI(vol) may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. KEY POINTS: • CTDI vol is related to liver CM enhancement in the parenchymal phase. • CTDI vol provides comparable information to body weight (BW). • CTDI vol may be used when automatically adjusting CM dose for patient size.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=213; abstract_english_function_words=64; abstract_english_share=0.3005; abstract_reads=english; language_check=metadata_listed