Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Unsupervised low-dose CT denoising using bidirectional contrastive network

Yuanke Zhang; Rui Zhang; Rujuan Cao; Fan Xu; Fengjuan Jiang; Jing Meng; Fei Ma; Yanfei Guo; Jianlei Liu (2024). Computer Methods and Programs in Biomedicine

DOI 10.1016/j.cmpb.2024.108206

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND AND OBJECTIVE: Low-dose computed tomography (LDCT) scans significantly reduce radiation exposure, but introduce higher levels of noise and artifacts that compromise image quality and diagnostic accuracy. Supervised learning methods have proven effective in denoising LDCT images, but are hampered by the need for large, paired datasets, which pose significant challenges in data acquisition. This study aims to develop a robust unsupervised LDCT denoising method that overcomes the reliance on paired LDCT and normal-dose CT (NDCT) samples, paving the way for more accessible and practical denoising techniques. METHODS: We propose a novel unsupervised network model, Bidirectional Contrastive Unsupervised Denoising (BCUD), for LDCT denoising. This model innovatively combines a bidirectional network structure with contrastive learning theory to map the precise mutual correspondence between the noisy LDCT image domain and the clean NDCT image domain. Specifically, we employ dual encoders and discriminators for domain-specific data generation, and use unique projection heads for each domain to adaptively learn customized embedded representations. We then align corresponding features across domains within the learned embedding spaces to achieve effective noise reduction. This approach fundamentally improves the model's ability to match features in latent space, thereby improving noise reduction while preserving fine image detail. RESULTS: Through extensive experimental validation on the AAPM-Mayo public dataset and real-world clinical datasets, the proposed BCUD method demonstrated superior performance. It achieved a peak signal-to-noise ratio (PSNR) of 31.387 dB, a structural similarity index measure (SSIM) of 0.886, an information fidelity criterion (IFC) of 2.305, and a visual information fidelity (VIF) of 0.373. Notably, subjective evaluation by radiologists resulted in a mean score of 4.23, highlighting its advantages over existing methods in terms of clinical applicability. CONCLUSIONS: This paper presents an innovative unsupervised LDCT denoising method using a bidirectional contrastive network, which greatly improves clinical applicability by eliminating the need for perfectly matched image pairs. The method sets a new benchmark in unsupervised LDCT image denoising, excelling in noise reduction and preservation of fine structural details.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=0; title_english_share=0.0000; title_reads=not_english; abstract_words=327; abstract_english_function_words=90; abstract_english_share=0.2752; abstract_reads=english; language_check=metadata_listed