Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

GCN-MIF: Graph Convolutional Network with Multi-Information Fusion for Low-dose CT Denoising

Kecheng Chen; Jiayu Sun; Shen Jiang; Jixiang Luo; Xinyu Zhang; Xuelin Pan; Dongsheng Wu; Yue Zhao; Bento, Miguel; Yazhou Ren; Xiaorong Pu (2021). arXiv (Cornell University)

DOI 10.48550/arxiv.2105.07146

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Being low-level radiation exposure and less harmful to health, low-dose computed tomography (LDCT) has been widely adopted in the early screening of lung cancer and COVID-19. LDCT images inevitably suffer from the degradation problem caused by complex noises. It was reported that deep learning (DL)-based LDCT denoising methods using convolutional neural network (CNN) achieved impressive denoising performance. Although most existing DL-based methods (e.g., encoder-decoder framework) can implicitly utilize non-local and contextual information via downsampling operator and 3D CNN, the explicit multi-information (i.e., local, non-local, and contextual) integration may not be explored enough. To address this issue, we propose a novel graph convolutional network-based LDCT denoising model, namely GCN-MIF, to explicitly perform multi-information fusion for denoising purpose. Concretely, by constructing intra- and inter-slice graph, the graph convolutional network is introduced to leverage the non-local and contextual relationships among pixels. The traditional CNN is adopted for the extraction of local information. Finally, the proposed GCN-MIF model fuses all the extracted local, non-local, and contextual information. Extensive experiments show the effectiveness of our proposed GCN-MIF model by quantitative and visualized results. Furthermore, a double-blind reader study on a public clinical dataset is also performed to validate the usability of denoising results in terms of the structural fidelity, the noise suppression, and the overall score. Models and code are available at https://github.com/tonyckc/GCN-MIF_demo.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=243; abstract_english_function_words=69; abstract_english_share=0.2840; abstract_reads=english; language_check=metadata_listed