Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Sequential screening for lung cancer in a high-risk group: randomised controlled trial

Stephen G Spiro; Pallav L. Shah; Robert Campbell Rintoul; Jeremy George; Sam M. Janes; Matthew E.J. Callister; Marco R. Novelli; Penny J. Shaw; Gabrijela Kocjan; Chris Griffiths; Mary Falzon; Richard Booton; N. Magee; Michael D. Peake; Paul Dhillon; Kishore Sridharan; Andrew Gordon Nicholson; Simon P.G. Padley; Magali N. Taylor; Asia Ahmed; Jack Allen; Yenting Ngai; Nyasha Chinyanganya; Victoria Ashford-Turner; Sarah Lewis; Dahmane Oukrif; Pamela H. Rabbitts; Nicholas Counsell; Allan K. Hackshaw (2019). European Respiratory Journal

DOI 10.1183/13993003.00581-2019

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low-dose computed tomography (LDCT) screening detects early-stage lung cancer and reduces mortality. We proposed a sequential approach targeted to a high-risk group as a potentially efficient screening strategy. METHODS: LungSEARCH was a national multicentre randomised trial. Current/ex-smokers with mild/moderate chronic obstructive pulmonary disease (COPD) were allocated (1:1) to have 5 years surveillance or not. Screened participants provided annual sputum samples for cytology and cytometry, and if abnormal were offered annual LDCT and autofluorescence bronchoscopy (AFB). Those with normal sputum provided annual samples. The primary end-point was the percentage of lung cancers diagnosed at stage I/II (nonsmall cell) or limited disease (small cell). RESULTS: 45.2% (14 out of 31) of controls with known staging were diagnosed with early-stage disease (one-sided p=0.24). Relative risk was 1.21 (95% CI 0.75-1.95) or 0.82 (95% CI 0.52-1.31) for early-stage or advanced cancers, respectively. Overall sensitivity for sputum (in those randomised to surveillance) was low (40.5%) with a cumulative false-positive rate (FPR) of 32.8%. 55% of cancers had normal sputum results throughout. Among sputum-positive individuals who had AFB, sensitivity was 45.5% and cumulative FPR was 39.5%; the corresponding measures for those who had LDCT were 100% and 16.1%, respectively. CONCLUSIONS: Our sequential strategy, using sputum cytology/cytometry to select high-risk individuals for AFB and LDCT, did not lead to a clear stage shift and did not improve the efficiency of lung cancer screening.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=224; abstract_english_function_words=73; abstract_english_share=0.3259; abstract_reads=english; language_check=metadata_listed