Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Investigation of Low-Dose CT Lung Cancer Screening Scan “Over-Range” Issue Using Machine Learning Methods

Donglai Huo; Mark Kiehn; Ann Scherzinger (2019). Journal of Digital Imaging

DOI 10.1007/s10278-019-00233-z

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (CT) lung cancer screening is recommended by the US Preventive Services Task Force for high lung cancer-risk populations. In this study, we investigated an important factor affecting the CT dose-the scan length, for this CT exam. A neural network model based on the "UNET" framework was established to segment the lung region in the CT scout images. It was trained initially with 247 chest X-ray images and then with 40 CT scout images. The mean Intersection over Union (IOU) and Dice coefficient were reported to be 0.954 and 0.976, respectively. Lung scan boundaries were determined from this segmentation and compared with the boundaries marked by an expert for 150 validation images, resulting an average 4.7% difference. Seven hundred seventy CT low-dose lung screening exams were retrospectively analyzed with the validated model. The average "desired" scan length was 252 mm with a standard deviation of 28 mm. The average "over-range" was 58.5 mm or 24%. The upper boundary (superior) on average had an "over-range" of 17 mm, and the lower boundary (inferior) on average had an "over-range" of 41 mm. Further analysis of this data showed that the extent of "over-range" was independent of acquisition date, acquisition time, acquisition station, and patient age, but dependent on technologist and patient weight. We concluded that this machine learning method could effectively support quality control on the scan length for CT low-dose screening scans, enabling the eliminations of unnecessary patient dose.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=2; title_english_share=0.1250; title_reads=english; abstract_words=238; abstract_english_function_words=87; abstract_english_share=0.3655; abstract_reads=english; language_check=metadata_listed