Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Coronary computed tomography angiography during arrhythmia: Radiation dose reduction with prospectively ECG-triggered axial and retrospectively ECG-gated helical 128-slice dual-source CT

Ashley M. Lee; Leif-Christopher Engel; Baiju Shah; Gary Liew; Manavjot S. Sidhu; Mannudeep Kalra; Suhny Abbara; Thomas J. Brady; Udo Hoffmann; Brian B. Ghoshhajra (2012). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2012.04.003

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Arrhythmia during coronary computed tomography angiography (coronary CTA) acquisition increases the risk of nondiagnostic segments and high radiation exposure. An advanced arrhythmia rejection algorithm for prospectively electrocardiogram (ECG)-triggered axial scans using dual-source CT (DSCT) examinations has recently been reported. OBJECTIVE: We compared image quality and effective dose at DSCT examinations using prospectively ECG-triggered axial scanning with advanced arrhythmia rejection software (PT-AAR) versus retrospectively ECG-gated helical scanning with tube-current modulation (RG-TCM) during arrhythmia. METHODS: This was a retrospective case-control study of 90 patients (43 PT-AAR, 47 RG-TCM) with arrhythmia (defined as heart rate variability [HRV] > 10 beats/min during data acquisition) referred for physician-supervised coronary CTA between April 2010 and September 2011. A subset of 22 cases matched for body mass index, HR, HRV, and other scan parameters was identified. Subjective image quality (4-point scale) and effective dose (dose length product method) were compared. RESULTS: PT-AAR was associated with lower effective dose than RG-TCM (4.1 vs 12.6 mSv entire cohort and 4.3 vs 9.1 mSv matched controls; both P < 0.01). Image quality scores were excellent in both groups (3.9 PT-AAR vs 3.6 RG-TCM) and nondiagnostic segment rates were low (0.1% vs 0.6%). Significantly higher image quality scores were found with PT-AAR in the entire cohort (P < 0.05), and in matched controls with high HRV > 28 beats/min (P < 0.05). CONCLUSIONS: In patients with variable heart rates, prospectively ECG-triggered axial DSCT with arrhythmia rejection algorithm is feasible and can decrease radiation exposure by ∼50% versus retrospectively ECG-gated helical DSCT, with preserved image quality.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=23; title_english_function_words=3; title_english_share=0.1304; title_reads=english; abstract_words=250; abstract_english_function_words=56; abstract_english_share=0.2240; abstract_reads=english; language_check=metadata_listed