Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography

Moritz Wyler von Ballmoos; Bernhard Haring; Pascal Juillerat; Hatem Alkadhi (2011). Annals of Internal Medicine

DOI 10.7326/0003-4819-154-6-201103150-00007

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available. PURPOSE: To summarize current evidence about the ability of low-dose coronary CT angiography to rule out coronary artery disease (CAD) in symptomatic adults. DATA SOURCES: Online databases, including MEDLINE, EMBASE, and the Cochrane Library, from inception through 31 October 2010; abstract databases; gray literature; reference lists of identified articles; and experts. No language restrictions were applied. STUDY SELECTION: All investigators screened and selected studies that compared prospective electrocardiography-gated coronary CT angiography with catheter coronary angiography (the reference standard) in symptomatic patients with suspected CAD. DATA EXTRACTION: Two investigators independently extracted patient and study protocol characteristics and rated methodological quality; differences were resolved by consensus or by a third reader. Multivariate random-effects models were used to obtain pooled estimates. DATA SYNTHESIS: 16 studies, comprising 960 patients, were found (7 studies of single-source, 64-slice CT; 4 of dual-source, 64-slice CT; 2 of single-source, 320-slice CT; 1 dual-source, 128-slice CT; 1 of single-source, 128-slice CT; and 1 of single-source, 256-slice CT). On average, 2.4% of the coronary arterial segments were of nondiagnostic image quality, and 1 or more segments were nondiagnostic in 9.5% of the patients. The patient-level sensitivity and specificity of CT angiography were 1.00 (95% CI, 0.98 to 1.00) and 0.89 (CI, 0.85 to 0.92), respectively. The pooled vessel- and segment-level estimates showed lower sensitivity and higher specificity than the patient-level estimates. Statistically significant heterogeneity was found between studies for vessel- and segment-level estimates, which seemed to be associated with body mass index and prevalence of CAD but not with CT scanner characteristics. LIMITATIONS: The small number of studies, half of which were from a single tertiary center, limits generalizability. The potential harms of the imaging tests were not well-evaluated. CONCLUSION: Early evidence suggests that low-dose coronary CT angiography matches the sensitivity of catheter-based angiography, has low radiation exposure, and is a potentially valid alternative to catheter angiography for triaging symptomatic patients with a clinical suspicion of CAD. PRIMARY FUNDING SOURCE: None.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=1; title_english_share=0.0833; title_reads=not_english; abstract_words=335; abstract_english_function_words=101; abstract_english_share=0.3015; abstract_reads=english; language_check=metadata_listed