Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Filter2Noise: a framework for interpretable and zero-shot low-dose CT image denoising

Yipeng Sun; Linda-Sophie Schneider; Siyuan Mei; Jinhua Wang; Ge Hu; Mingxuan Gu; Chengze Ye; Fabian Wagner; Lan Song; Siming Bayer; Andreas Maier (2026). Journal of medical imaging

DOI 10.1117/1.jmi.13.2.024004

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PurposeDeep learning has achieved remarkable progress in low-dose computed tomography (LDCT) denoising; however, radiologists struggle to trust black-box models they cannot verify or control. Zero-shot methods eliminate training data requirements but fail on computed tomography’s (CT) spatially correlated noise. We demonstrate that a transparent mathematical operator, when made content-adaptive, can match deep learning performance while remaining fully interpretable.ApproachWe introduce Filter2Noise (F2N), which replaces conventional deep networks with an attention-guided bilateral filter that adapts to local anatomy. A lightweight attention module (3.6k parameters) predicts optimal filtering strategies for each image region by analyzing tissue type, texture, and noise characteristics. To enable robust learning from a single noisy image with correlated noise, we develop Euclidean local shuffle, which strategically disrupts noise correlations while preserving anatomical structure, and a multi-scale self-supervised loss that enforces consistency across resolutions.ResultsOn the Mayo Clinic LDCT Grand Challenge, F2N achieves 39.76 dB peak signal-to-noise ratio, outperforming the next-best zero-shot method by 1.88 dB, while using 360× fewer parameters (3.6k versus 1.3M). Clinical validation on photon-counting CT demonstrates that F2N elevates low-dose images to full-dose quality (no statistically significant difference in contrast-to-noise ratio, p=0.10). The learned filtering strategy is fully visualizable: parameter maps reveal content-aware behavior. Radiologists can interactively adjust these parameters post-training to refine denoising in diagnostically critical regions.ConclusionsF2N reconciles competitive performance with complete interpretability and user control, providing radiologists with a verifiable tool that works across scanners and protocols without retraining.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=258; abstract_english_function_words=57; abstract_english_share=0.2209; abstract_reads=english; language_check=metadata_listed