Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT

Xin Sui; Felix G. Meinel; Wei Song; Xiaoli Xu; Zixing Wang; Yuyan Wang; Zhengyu Jin; Jiuhong Chen; Rozemarijn Vliegenthart; Uwe Joseph Schoepf (2015). European Journal of Radiology

DOI 10.1016/j.ejrad.2015.12.013

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: In this study, the accuracy of ultra-low-dose computed tomography (CT) with iterative reconstruction (IR) for detection and measurement of pulmonary nodules was evaluated. METHODS: Eighty-four individuals referred for lung cancer screening (mean age: 54.5±10.8 years) underwent low-dose computed tomography (LDCT) and ultra-low-dose CT. CT examinations were performed with attenuation-based tube current modulation. Reference tube voltage and current were set to 120kV/25mÅs for LDCT and 80kV/4mÅs for ultra-low-dose CT. CT images were reconstructed with filtered back projection (FBP) for LDCT, and with FBP and IR for ultra-low-dose CT datasets. A reference standard was established by a consensus panel of 2 different radiologists on LDCT. Volume and diameter of the solid nodules were measured on LDCT with FBP and ultra-low dose CT with FBP and IR. Interobserver and interscan variability were analyzed and compared by the Bland-Altman method. RESULTS: A total of 127 nodules were identified, including 105 solid nodules, 15 part solid nodules, 7 ground glass nodules. On ultra-low-dose CT scans, the effective radiation dose was 0.13±0.11mSv. A total of 113 (88.9%) and 110 (86.6%) true-positive nodules with FBP versus 117 (92.1%) and 118(92.9%) with IR were detected by two observers, respectively. The volume and size of the 105 solid nodules were measured, with mean volume/diameter of 46.5±46.6 mm(3)/5.1±1.6mm. There was no significant difference in nodule volume or diameter measurements between ultra-low-dose CT and LDCT protocols for solid nodules. CONCLUSIONS: Ultra-low-dose CT with iterative reconstruction has high sensitivity for lung nodule detection without significant difference in nodule size and volume measurement compared to LDCT.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=5; title_english_share=0.2500; title_reads=english; abstract_words=263; abstract_english_function_words=81; abstract_english_share=0.3080; abstract_reads=english; language_check=metadata_listed