Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Artificial Intelligence for Nodule Detection in Thoracic Computed Tomography: A Systematic review and Structural Analysis Based on the MI-CLAIM Model
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background: Lung cancer remains a leading cause of cancer-related mortality, predominantly due to late-stage diagnosis. Lowdose Computed Tomography (LDCT) screening can reduce mortality but implementation is often challenged by already limited radiology resources. Artificial intelligence (AI) has the potential to improve CT-based lung nodule detection, but systematic and unified reporting on data sources, development, and model performance remains limited. This review applies MI-CLAIM and QUADAS-2 to assess methodological quality and reporting, following PRISMA-P guidelines1. Objectives: 1) Identify AI applications for thoracic CT nodule detection and their diagnostic accuracy. 2) Evaluate clinical implications, validation setup and data foundation. 3) Assess adherence to the MI-CLAIM checklist. Methods: Databases (Medline, IEEE Xplore, Web of Science, Embase, Cinahl, Scopus, Cochrane, Google Scholar) were systematically searched using an adapted search string for the respective databases, developed with a trained librarian. Two named reviewers1,2 independently screened, and a third³ resolved disagreements. Data extraction focused on PICO elements, diagnostic performance, and reporting and bias with MI-CLAIM and QUADAS-2 adherence. The search concluded on the 27th of December 2024 Results Of 11,875 records identified, 8,729 remained after removal of duplicates. After title and abstract screening, 93 full-text articles were assessed, and 23 met the inclusion criteria. Most included studies were published after 2019 and were based on retrospective hospital CT datasets. According to QUADAS-2, 11 studies had low risk of bias. Mean MI-CLAIM adherence was 65%, and 3 of 23 studies achieved high reporting completeness. Reported AI sensitivities ranged from 59.2% to 98.8%, and false-positive rates from 0.067 to 2.4 per scan. Validation was mainly retrospective, with only 3 studies using prospective data. Conclusion: AI for thoracic CT nodule detection shows promising but heterogeneous diagnostic performance, mostly based on retrospective, single-centre data with incomplete reporting. Before routine clinical use, robust external validation studies with prospective design and transparent reporting are required.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=21; title_english_function_words=6; title_english_share=0.2857; title_reads=english; abstract_words=296; abstract_english_function_words=78; abstract_english_share=0.2635; abstract_reads=english; language_check=metadata_listed