Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Deep Learning-Based Enhancement of Low-Dose Computed Tomography Images using Generative Adversarial Networks
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background: Reducing radiation dose in Computed Tomography (CT) is a clinical imperative, yet current low-dose CT (LDCT) protocols are inherently limited by noise and artifacts that obscure critical diagnostic details. While traditional iterative reconstruction and standard deep learning models have been proposed, they often introduce undesirable "waxy" textures and loss of fine structural edges. Methods: This study presents a high-fidelity image enhancement framework based on Generative Adversarial Networks (GANs) specifically optimized for LDCT denoising. Our approach integrates a multi-scale U-Net generator with a discriminator that evaluates both global structure and local texture. To ensure clinical reliability, we utilize a composite loss function comprising pixel-wise MSE, adversarial loss, and VGG-based perceptual loss, which encourages the model to preserve biologically relevant high-frequency details. Results: Experimental evaluation on the AAPM-Mayo Clinic dataset demonstrates that our proposed model significantly outperforms state-of-the-art methods, achieving a Peak Signal-to-Noise Ratio (PSNR) of 32.56 dB and a Structural Similarity Index (SSIM) of 0.912. Qualitative assessments confirm that our framework effectively suppresses quantum noise while maintaining the natural stochastic texture of CT images, facilitating better visualization of subtle lesions compared to standard CNN-based denoising. Conclusion: The proposed GAN-based framework bridges the gap between dose reduction and image quality, providing a viable pathway for high-quality diagnostic imaging at a fraction of the standard radiation exposure. This method holds significant potential for routine clinical use, particularly in screening scenarios where repeated exposure is a concern.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=1; title_english_share=0.0714; title_reads=not_english; abstract_words=248; abstract_english_function_words=67; abstract_english_share=0.2702; abstract_reads=english; language_check=metadata_listed