Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Application of automatic tube current modulation combined with iterative reconstruction algorithm in low- dose CT pulmonary angiography

Changjiu He; Shibei Hu; Guohui Xu; Li Hailie; Fang Liu; Bin Feng; Peng Zhou (2016). Zhonghua fangshe yixue yu fanghu zazhi

DOI 10.3760/cma.j.issn.0254-5098.2016.11.012

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Objective To explore the application value of automatic tube current modulation combined with iterative reconstruction algorithm (idose4) in low-dose computed tomography pulmonary angiography (CTPA). Methods A total of 80 patients with CTPA collected continuously were randomly divided into control group (n=40, 80 kV, 180 mAs) and experimental group (n=40, 80 kV, automatic tube current modulation). The data sets of control group were reconstructed with filtered-back-projection algorithm (group A), and the data sets of experimental group were reconstructed with filtered-back-projection algorithm (group B) and iterative reconstruction algorithm (group C). Subjective score, mean CT values of pulmonary artery, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were recorded. Effective dose (E) was compared. Results The E of experimental group was decreased by 36.8% compared to control group (t=-3.998, P 0.05). There was statistically significant difference for the SNR, CNR and image noise of 3 groups (F=10.411, 7.630, 13.021, P 0.05). Conclusions Using automatic tube current modulation combined with iterative reconstruction algorithm in low-dose CTPA could meet the requirements of image quality, and reduce the radiation dose to a certain extent. Key words: Computed tomography pulmonary angiography; Radiation dose; Iterative reconstruction; Automatic tube current modulation

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=3; title_english_share=0.1765; title_reads=english; abstract_words=193; abstract_english_function_words=48; abstract_english_share=0.2487; abstract_reads=english; language_check=metadata_listed