Simulation education utilizing phantom and angle reference guide in pulmonary nodule CT localization

Chiao-Yun Tsai; Stella Chin‐Shaw Tsai; Ming-Yu Hsieh; Guang-Qian Shen; Guan-Liang Robert Guo; Zhe-Luen Tsui; Cadmus C. A. Yuan; Frank Cheau‐Feng Lin (2023). Heliyon

DOI 10.1016/j.heliyon.2023.e18329

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Objective: The incidence of sub-centimeter pulmonary nodules has been increasing along with the use of low-dose computed tomography (LDCT) as a screening tool for early lung cancer detection. In our institution, pulmonary nodule computed tomography-guided localization (PNCL) is performed preoperatively with the laser angle guided assembly (LAGA), an angle reference device. This study aims to investigate the efficacy of postgraduate education in a phantom simulation of PNCL, with or without LAGA. Setting design: test, univariate and multivariate linear regression were used for statistical analyses. Results: The confidence level increased from median 7[range 1, 9] to 8, range [6,9] (p = 0.001) before and after the simulation education course. The scores of enhanced PNCL ability and course satisfaction were as high as 8 [5,9], and 9 [7,9]. LAGA enabled broader puncture angles (with 27.5° [0°,80°]; without 14° [0°, 80°], p = 0.003), a lower puncture frequency (with 1 [1,4]; without 2 [1,5], p < 0.001), and a smaller angle deviation (with 3°[ 0°,8°]; without 5°[ 0°,19°], p = 0.002). Pleural depth in millimeters was associated with increased puncture frequency (0.019[0,010,0.028]) and procedure time (0.071'[ 0.018,0.123']. The PNCL-experienced physicians performed the procedure in less time (-2.854'[-4.646',1.061']. The traverse direction toward the mediastinum diminished the frequency (toward 1[ 1,3]; away 1 [1,5], p = 0.003) and time (toward 7.5'[2',18]'; away 9'[ 3',31'], p = 0.027). The learning curve did not improve procedure performance after ten PNCL simulation rounds. Conclusions: The phantom PNCL simulation education course increased the confidence level, enhanced residents' skill acquisition, and promoted learning satisfaction. The angle reference device helped improve the outcomes of the puncture frequency and reduced angle deviation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=230; abstract_english_function_words=79; abstract_english_share=0.3435; abstract_reads=english; language_check=metadata_listed